E-4
Operating Function System Parameter Setting Function
Adjustment Item Content of Function Initial Value Range Remark
Meter Panel Control (ON/OFF)
To set [0] means no parameter setting on meter panel
is available by an operator.
1 (Display) 1: Display Control Valid
Operating hrs Display Switch
To set display or non-display of operating hours in
traveling and materials handling.
0
0: Non-display
1: Display
Alarm start time warning No parkg brake
To set a time of starting to alarm for no parking brake
applied when an operator leaving the seat.
3
(sec)
1 - 240
(sec)
Alarm continuation time
To set a time of continuation for alarming no parking
brake applied after starting to beep.
30
(sec)
5 - 240
(sec)
Alarm sound continuation time after
Key switch OFF
To set a time of continuation for alarming no parking
brake applied after key switch turns OFF.
5
(sec)
5 - 240
(sec)
Operating hrs display setting, R/L motor
To switch displays of F/R ON time and motor
conductivity time.
0
0: F/R switch ON
1:Motor conductivity
Operating hrs display setting, P motor
To switch displays of materials handling lever control
time and motor conductivity time.
0
0: lever control
1: Motor conductivity
0: Materials handling lever control
Load Capacity Parameter Setting
Adjustment Item Content of Function Initial Value Range Remark
Lift Cylinder Pressure Receiving Area
In case of triple and full free mast, pressure receiving
area on lift cylinder piston indicates the value on
main cylinder (rear side).
-
0.00 - 50.00
(cm
2
)
It may change depending on mast of type and
height.
Zero Point Setting Oil Pressure
It is the oil pressure being received on lift cylinder
section when unloaded.
-
5.00 - 20.00
(kg/cm
2
)
It may change depending on mast of type and
height.
Load Capacity Calculation Coefficient
It is the coefficient to be applied to calculate load
capacity based on oil pressure.
-
0 - 2.0
It may change depending on mast of type and
height.
Oil Pressure Obtaining Device Switch To classify counter-balanced truck and reach truck.
-
1: Reach
2:Counter-balanced
Overload alarm Function ON/OFF Switch
To set ON/OFF switch for alarming overload when
exceeding presetting load capacity.
-
0: OFF
1: ON
It may change depending on mast of type and
height.
Overload Alarming Load It is the load for alarming overload.
-
0.50 - 3.00
(ton)
It may change depending on mast of type and
height.
Overload Alarm OFF Load Difference
It is the load to be deducted from alarming load to
stop alarming.
-
0.10- 0.40
(ton)
It may change depending on mast of type and
height.