E(AR)-9
Easy-to-set Value List
When pressing the [soft] and [power] buttons in the parameter set menu, the values are as shown below.
【Soft】 Button Set Value
・ When desiring to set the soft cargo-handling and soft lift stop by making the deceleration and acceleration gentle to transport the fragile products, set as follows.
Name Initial Value Soft Message
Power level set (L/M/H/U) 2 0
0:U/1:L/2:M/3:H
U mode travel power 2 1
1:L/2:M/3:H
U mode ES volume 6 1
1:Weak acceleration , 8:Strong acceleration
Travel accelerator open property 2 3 1:T/N ,2: Standard 3: Low speed 4:S
Regenerator braking force adjustment (FR plugging) 100 50 0: Invalid 100: Strong braking
Regenerator braking force adjustment (brake) 60 40 0: Invalid 100: Strong braking
Regenerator braking adjustment (accelerator neutral) 60 40 0: Invalid 100: Strong braking
U mode cargo-handling power 2 1
1:L/2:M/3:H
U mode lift 1 speed 100 60 Adjustable at every 10%
U mode lift 2 speed 100 60 Adjustable at every 10%
U mode tilt speed 100 50 Adjustable at every 10%
U mode reach speed 100 50 Adjustable at every 10%
ATT1 speed 90 50 Adjustable at every 10%
ATT2 speed 100 50 Adjustable at every 10%
【POWER】 Button Set Value
・ When desiring to perform the work powerfully, set as follows.
Name Initial Value Power Message
Power level set (H/M/L/U) 2 0
0:U/1:L/2:M/3:H
U mode travel power 2 3
1:L/2:M/3:H
Travel accelerator open property 2 1 1:T/N, 2: Standard,3: Low speed ,4:S
U mode Cargo-handling power 2 3
1:L/2:M/3:H