E(AR)-10
When pressing the [User] button in the parameter set menu and selecting the [T_Mode][N_Mode], the files are as shown below.
【T_Mode】 File Set Value
Name Initial Value T_Mode Message
Power level set (L/M/H/U) 2 0
0:U/1:L/2:M/3:H
U mode travel power 2 3
1:L/2:M/3:H
Travel soft start property 2 4
1:Strong acceleration in low speed region
2: Middle 3: Strong acceleration in high speed region 4:T , 5:N , 6:S
Travel accelerator open property 2 1 1:T /N , 2: Standard , 3: Low speed 4:S ,
Lift lever open property 1 3 1: Potentiometer control (standard) 3: Micro-switch(ON/OFF)control
【N_Mode】 File Set Value
Name Initial Value N_Mode Message
Power level set (L/M/H/U) 2 0
0:U/1:L/2:M/3:H
U mode travel power 2 3
1:L/2:M/3:H
Travel soft start property 2 5
1:Strong acceleration in low speed region
2: Middle 3: Strong acceleration in high speed region 4:T , 5:N , 6:S
Travel accelerator open property 2 1 1:T /N , 2: Standard , 3: Low speed 4:S ,
Lift level open property 1 3 1: Potentiometer control (standard) 3: Micro-switch(ON/OFF)control