DOMEKT
User Manual
EN

Other manuals for Komfovent DOMEKT R 400 V

Questions and Answers

  • S
    smithstephanieAug 16, 2025
    How to fix low supply air flow in my Komfovent Fan?
    • K
      Keith SchroederAug 16, 2025
      If you're experiencing low supply air flow with your Komfovent Fan, here are a few things to check: * Make sure your air filters aren't dirty. If they are, replace them. * Check for any obstructions in your air ducts, dampers, or inlet/exhaust openings. * If you're using VAV air flow control, ensure the pressure sensors are properly connected. If VAV isn't needed, switch to CAV or DCV in the settings. * If the above doesn't resolve the issue, the supply air fan may not be working, and you should contact authorised service.
  • M
    Matthew MacdonaldAug 19, 2025
    How to troubleshoot low extract air flow in my Komfovent Fan?
    • D
      David MaynardAug 19, 2025
      If you're experiencing low extract air flow with your Komfovent Fan, here are a few things to check: * Make sure your air filters aren't dirty. If they are, replace them. * Check for any obstructions in your air ducts, dampers, or inlet/exhaust openings. * If you're using VAV air flow control, ensure the pressure sensors are properly connected. If VAV isn't needed, switch to CAV or DCV in the settings. * If the above doesn't resolve the issue, the extract air fan may not be working, and you should contact authorised service.
  • M
    Matthew BurnsAug 25, 2025
    Why is the return water temperature low in my Komfovent Fan?
    • B
      bpenaAug 26, 2025
      If you are experiencing a low return water temperature in your Komfovent Fan, consider the following: * Verify that there is hot water in the water heater system. * Check if the circulation pump is working correctly. * Ensure the water control valve is opening properly. * Confirm that the return water temperature sensor is correctly installed as per the installation manual. If issues persist, contact your installer or authorized service.
  • J
    James TownsendAug 27, 2025
    How to fix a heat exchanger failure in my Komfovent Fan?
    • R
      rodriguezpaulaAug 27, 2025
      If you are experiencing a heat exchanger failure in your Komfovent Fan, here are some things to check: * For DOMEKT R devices, check for any obstructions preventing the rotor heat exchanger from rotating and inspect the rotor belt for tears. * For DOMEKT CF units, if the air bypass damper of the counter-flow heat exchanger is malfunctioning, contact authorised service.
  • V
    Vanessa JohnsonAug 30, 2025
    Why is the supply air temperature low in my Komfovent Fan?
    • T
      Taylor BlackburnAug 30, 2025
      If the supply air temperature from your Komfovent Fan is too low, it could be due to: * Integrated heaters not working: Contact authorised service. * Additional heating/cooling devices faulty or incorrectly installed: Contact the company that installed or sold the equipment. * Faulty air temperature sensor: Contact authorised service.
  • B
    bairdwayneSep 1, 2025
    What causes high supply air temperature in Komfovent Fan?
    • G
      ggarciaSep 1, 2025
      If the supply air temperature from your Komfovent Fan is too high, it could be due to: * Integrated heaters malfunctioning: Contact authorised service. * Additional heating/cooling devices malfunctioning or incorrectly installed: Contact the company that installed or sold the equipment. * Faulty air temperature sensor: Contact authorised service.
  • K
    Kari PenaSep 4, 2025
    Why is the heat exchanger icing up in my Komfovent Fan?
    • R
      Rebecca MoralesSep 4, 2025
      If your Komfovent Fan's heat exchanger is icing up, it could be due to: * Malfunctioning antifreeze protection: Check the antifreeze protection settings and ensure any external pre-heater being used is working correctly. * Antifreeze protection switched off: Verify the antifreeze protection settings. If you're not using an integrated or external pre-heater, you can't use a device with a counter-flow heat exchanger when the outside temperature drops below -4 °C.
  • R
    Regina ButlerSep 7, 2025
    What causes low heat exchanger efficiency in Komfovent Fan?
    • C
      Chris VillaSep 7, 2025
      If a message indicates low heat exchanger efficiency in your Komfovent Fan, here are some potential causes and solutions: * If air is being extracted through an additional branch (only for DOMEKT R devices), and that's not needed, close the fifth branch. Ensure any air closing damper in the auxiliary extraction duct is completely closed. * If the supply air volume significantly exceeds the extract air volume and this difference isn't required, unify the air flow settings. * If the unit door isn't fully closed, leading to mixed air flows, ensure the door is firmly pressed shut and that the gaskets aren't worn.
  • S
    sarah41Sep 10, 2025
    What triggers an internal fire alarm in my Komfovent Fan?
    • M
      Meghan PhillipsSep 10, 2025
      If your Komfovent Fan is showing an internal fire alarm, it may be triggered because: * The internal air temperature is above 50°C: Locate the heat source in the ductwork or unit. * Faulty temperature sensor: Contact authorised service.
  • M
    Matthew KirkSep 12, 2025
    What to do, if my Komfovent Fan indicates clogged air filters?
    • J
      Jessica CostaSep 13, 2025
      If your Komfovent Fan indicates clogged air filters, switch off the device and replace the air filters. After replacement, delete the message.

Summary

Introduction

Air Handling Unit Functions

Air Flow Control

Explains methods for adjusting fan speed to manage air volume in the unit.

Temperature Control

Details how the unit maintains desired air temperature using heat exchangers or auxiliary devices.

Standard Operating Modes

Describes the four preset modes (AWAY, NORMAL, INTENSIVE, BOOST) for ventilation intensity and temperature.

Special Operating Modes

Outlines KITCHEN, FIREPLACE, OVERRIDE, and HOLIDAYS modes with specific durations and settings.

ECO Mode

Details the energy-saving mode focused on reducing consumption by optimizing heating/cooling and fan speed.

AUTO Mode

Explains automatic ventilation based on weekly schedules or indoor air quality.

Control and Settings

Control Panel C6.1 Operation

Details operation, parameter overview, mode changes, settings, and advanced options for the C6.1 panel.

Control Panel C6.2 Features

Describes C6.2 panel functions including turning on/off, messages, sounds, and keypad lock.

Smartphone Control Methods

Guidance on using mobile apps ('Komfovent Home'/'Cloud') to remotely control the unit.

Computer and Web Interface Control

Controlling the unit via a web browser, including operation modes, settings, and schedules.

Troubleshooting

Troubleshooting: Message Table

A list of error codes, possible causes, and user actions for resolving unit faults.

Troubleshooting: C6.2 Indicator Lights

Explanation of LED indicators on the C6.2 panel for operation status and malfunctions.

Periodical Maintenance

Filter Inspection and Replacement

Procedures for checking, replacing, and calibrating air filters for optimal performance.

Device Maintenance Journal

A log table for recording performed maintenance and repair works for warranty purposes.

Komfovent DOMEKT R 400 V Specifications

General IconGeneral
Airflow rate400 m³/h
Heat recovery efficiencyup to 90%
MountingVertical
Power supply230 V
Filter classF7