EasyManua.ls Logo

Koolaire KDT0500A - Installation

Default Icon
152 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Part Number STH063 9/17 15
Location of Ice Machine
The location selected for the ice machine must meet the
following criteria. If any of these criteria are not met,
select another location.
The location must be indoors.
The location must be free of airborne and other
contaminants.
Air temperature: Must be at least 40°F (4°C) but must
not exceed 110°F (43.4°C).
The location must not be near heat-generating
equipment or in direct sunlight.
The location must be capable of supporting the weight
of the ice machine and a full bin of ice.
The location must allow enough clearance for water,
drain, and electrical connections in the rear of the ice
machine.
The location must not obstruct airflow through or
around the ice machine (condenser air flow is in
the back and out the sides). Refer to the chart for
clearance requirements.
The ice machine must be protected if it will be
subjected to temperatures below 32°F (0°C). Failure
caused by exposure to freezing temperatures is not
covered by the warranty.
Installation

Table of Contents

Related product manuals