EasyManua.ls Logo

KOOMANDO TM5886 - Technical Specifications; Working Voltage; Working Temperature; Working Time

KOOMANDO TM5886
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Control panel
TM5886 e TM5895
for tubular motors and dampers
Users Manual Control Panel
TECHNICAL SPECIFICATIONS
Working Voltage: 85 - 265Vac
(110Vac 60Hz / 220VAC 50HZ)
Working temperature: -20ºC to + 60 ° C
Working time: 100s
Engine capacity: 1 HP (735W), 220Vac
or 0.5 HP, 110Vac
Integrated fuse: circuit (0.5A), motor (10A 250V)
Working frequency: 433.92MHz
Memorized remote controls max: 30
Size: 150x100x40 mm
Weight: 245 gr
IP56 protection
II. SAFETY INSTRUCTIONS
- Please read this manual before commissioning.
- Make sure the machine is not live before open the equipment
cover.
- Clear the memory before the commissioning of the unit
(ref. Erasing the memory).
- The signal can be disturbed by other communication devices.
- The unit must only be used for manual control and / or via radio
of geared motors for roller shutters.
The use for the control of high-risk systems.
- Each safety risk must be eliminated before use.
- If necessary, replace fuses with one of the same tics.
III. ELECTRICAL CONNECTIONS
I.
1
2
3
4
5
6
7
8
9
10
CAUTION
If the unit is installed outdoors, it is advisable to disconnect the at cable of the buttons.
If the motor is controlled by pushbuttons or key selector (see Diagram 1), the connection must be modied so that the motor
cables are connected to the control unit without interruption (see Diagram 2).
Diagram 1 Diagram 2
Pushbuttons or
key selector
Pushbuttons or
key selector
Control unit
Motor
Motor
10-11
output 12 Vac supply to
photocells
13-14 connection NC photocell:
if not used, leave bridged
L - N input line 220
EG ne-line-engine land
COM - ▲ - ▼ engine output
ashing light output 220V
or courtesy light
12V - GND output power photocells
N.C. photocells
◄► - COM input opening button (N.O.)
- COM input stop button (N.O.)
►◄ - COM input closing button (N.O.)
- COM step by step button input
(OPEN - STOP-CLOSE- STOP ...)
Connections
+12 +12
- GND
0
V
DIP1
ON or OFF changes the
direction of movement of
the motor
DIP2
ON single button control
OFF 3 control keys
DIP3 (outputs 8-9)
ON
ashing light
OFF xed light
DIP4
ON deadman
OFF semiautomatic
EN
www.koomando.com - remote control store