SOUND
SYNTHF”‘”
I
PARAMETER NAMES AND
F’JNCTlOtiS
RCV
CH
(Receive
Channel)
/
I
There can be
up
to 16 separate CHAVNELS of MIDI
signals on a single MIDI bus line (5 pm DIN cable).
The RECEIVE CHANNEL
parameier
delermines
which channel
the
Poly-600
will
respond
to (the
olhar
channels will be ignored,
even
if
Ihey’+e
carrying MIDI
signals).
When connecting two
Poly-600s
together,
selecling
Channel 1 on the second keyboard will
cause
it
to
sound
Ihe
notes physically played on
the
firs1
keyboard. Selecting Channel 2 will cause the receiv-
ing keyboard to sound the notes played by the se-
quencer in the
lirst
keyboard. In either case, the se-
cond keyboard will still sound notes played on IT’S
keyboard.
This parameter will slay even if you
turn
off
the
power.
RECEIVING
CHANNEL
!
VALUE
CH.!6
16
i
CH.
I
I
‘.
PROG CHANGE (Program Change)
The
Poly-600
MIDI interface can transmit and receive
Program Changes. if desired. With PROG CHANGE
set to ENABLE (value
i
).
the
Poly-600
will respond
to any Program Change codes received
ovar
the
selected MIDI channel. With PROG CHANGE set
to
DISABLE (Value
c
),
the
Poly-800
wilt IGNORE any
Program Change codes received over MIDI.
With
hvo
Poly-600s
(or other compatible keyboards)
linked together using MIDI. you can change programs
on either unit and the other will change lo
the
same
program number.
By
moving different programs into
the same program numbers on each unit (i.e..
Prog.
3
:
is strings on one unit, brass on
Ihe
second), two
differenl
programs can be “layered”
togelher.
When you link Iwo
Poly-600s
togelher.
set
PROG
CHANGE on both units lo the ENABLE position (value
;
).
The PROG CHANGE parameter
controls
recep-
tion of
Program Change signals.
.
This parameter will be reset to DISABLE when the
power Is turned on.
PROG CHANGE
VALUE
I
Program change
1
No
change
@
SEQ CLK (Sequencer Clock)
Determines how
lhe
Polyphonic Sequencer is
controlled
INT(:
)
EXT(,J)
The
lronl
panel SPEED control and the
START/STOP switch conlrot
the
Sequencer.
Clock and control signals received over
the
MIDI bus control the Sequencer.
This parameter will be
reset
to
tNT
when the
power is turned on.
SE0
CLK