ADJUSTMENT
PROCEDURE
Caution:
This
product
has
been
thoroughly
abjusted
at
the
factory
before
shipment.
Therefore
do
not
abjust
anything
other
than
those
VRs
required
for
servicing.
BEFORE
making
any
calibration
abjustments,
Be
sure
that
test
data
is
loaded
into
POLY-800.
The
following
setting
chart
shows
the
program
data
used
for
servece
testing.
After
inputting
the
data,
save
it
on
tape
for
future
time saving
convenience.
PROGRAM
no.
11
(noise
level):
Parameter:
Value:
17
0
18
1
31
99
32
0
33
0
35
0
37
15
61
0
62
0
63
31
64
0
65
31
66
0
83
0
84
0
PROGRAM
Parameter:
Value:
PROGRAM
Parameter:
Value:
PROGRAM
Parameter:
Value:
no.
11
2
no.
11
2
no.
11
2
21
12
2
13
12
2
14
12
2
(master
oscillator):
13
14
1
0
15
16
0 0
(cut
off):
13
14
1
0
15
16
0 0
17
30
17
31
(resonance):
13
14
1
0
15 16
0
0
17
31
18
1
18
1
18
1
31
60
31
12
31
99
32
0
32
12
32
15
33
0
33
2
33
0
35
0
35
0
35
0
38
0
37
0
37
0
41
0
41
0
41
0
42
0
42
0
42
0
43
31
43
31
43
31
44
0
44
0
44
0
45
31
45
31
45
31
46
0
46
0
46
0
83
0
83
0
81
15
84
0
84
0
82
83
84
0 0
0
PROGRAM
Parameter:
Value:
PROGRAM
Parameter:
Value:
no.
11
1
no.
11
1
15
12
1
16
12
1
(delay
1):
13
14 15 16
1111
(delay
2):
13
14
15
16
1111
17
31
17
31
18
1
18
1
31
99
31
99
32
0
32
0
33
0
33
0
35
1
35
1
37
0
37
0
41
0
41
0
42
0
42
0
43
7
43
7
44
0
44
0
45
0
45
0
46
0
46
0
61
0
61
0
71
50
71
0
72
15
72
0
73
0
73
0
74
0
74
0
75
15
75
15
76
0
76
0
77
0
77
0
81
0
81
0
82
0
82
0
83
0
83
0
84
0
84
0
85
2
85
2
86
1
86
1
81
1
81
1
88
0
88
0
1.
Power
supply
circuit
(KLM-1032)
Be
sure
that
the
specified
AC
adapter
is
used:
9V,
300mA,
1)
+5V
check
and
adjustment:
Use
a
DVM
(digital
voltmeter)
to
check
KLM-596
connector
CN6
Pin
6
and
confirm
+ 5V
(=h
0.005V).
Adjust
VR1
if
necessary.
2)
-5V
check:
Use
a
DVM
to
check
KLM-596
connector
CN6
Pin
8
and
con
firm
-5V
(within
-
4.7V
~
-5.7V)
2.
D/A
converter
check
and
adjustment
(KLM-1032)
]
With
joystick
bend
control
at
center
position:
(BEND
INT
MAX)
connect
DVM
to
KLM-596
IC10
(TL062)
Pin
7
and
confirm
1.986V
±
0.005V.
Adjust
VR4
if
necessary.
Reference
data:
3.990V
for
an
upward
pitch
bend
and
0.020V
for
a
downward
pitch
bend.
Note:
Adjustment
is
easiest
in
the
joystick
circuit
although
the
idea
is
to
obtain
a
4V
±
0.004V
output
from
IC
38
(TL062)
by ad
justing
the
D/A
converter
when
IC
81C55
port
A
output
is
all
high.
13.
Noise
level
check
and
adjustment:
(KLM-1032)
1)
Select
program
no.
11.
2)
Depress
C3
key
and
set
to
HOLD.
3)
Connect
on
oscilloscope
to
KLM-596
CN6A
3
pin
and
con
firm
noise
level
of
0.3Vp-p
(±20%).
4)
Adjust
VR3
if
necessary.

Related product manuals