2.
FEEDBACK
TIME
Verification,
Adjustment
1)
Select
program
No.
15.
2)
Connect
on
oscilloscope
(AC,
50mV/div,
0.1
sec/div)
to
TP1.
3)
Play
C3
key,
and
check
that
the
envelope
of
the
waveform
(from
peak
of
waveform
to
decay)
is
600msec
±
50msec.
(Fig-2)
4)
Adjust
VR
1
if
necessary
AC50m/m
O.isec
600msec
Fig-2
3.
ANALOG
COMPANDER
NE572
Verification,
Adjustment
1)
Select
program
No.
16.
2)
Connect
on
oscilloscope
(AC
50mV/div,
0.1
sec/div)
to
TP1.
(Connect
ground
to
TP2)
3)
Play
C3
key,
and
check
on
the
oscilloscope
that
visible
waveforms
are
formed
which
are
unifprm
in
size
and
shape.
Note:
Although
this
can
be
abjusted
via
VR2,
because
it
is
fixed
at
a
fully
couterclockwise
position,
so
it
should
not
be
turned.