Conguration and parameters view
Set the minimum temperature value then push and keep knob for about 5 seconds until
the display shows „>T SETPOINT”. Turn a knob to select the required value. There are
some parameters that are not changeable by the user (e.g. >T INLET, >POWER), or can be
used to change the work conguration only (e.g. display brightness, language version).
To change the parameters value push (position ickering) and turn the knob. Push the
knob to conrm a change.
Notice: conrm a new parameter value within 10 seconds, otherwise you will lose it.
The new parameter value will be saved when you exit menu using [>EXIT].
You can switch between the following parameters:
[>T SETPOINT] temperature (min-max) - °C,
[>T INLET] inlet temperature value - °C,
[>T OUTLET] outlet temperature value - °C,
[>FLOW] ow rate - l/min,
[>POWER] percentage of maximum power with which the unit currently heats, -%,
[>T - h] work time,
[>BRIGH MIN] minimum brightness / stand-by-mode (0 - BRIGH MAX),
[>BRIGH MAX] maximum brightness / active (BRIGH MIN -25),
[>ENGLISH] select language version,
[>TEMP LIMIT] maximum temperature limit (min setting - max setting),
Notice: a new maximum temperature value will be saved in memory for other
temperature settings as well,
If you try to set the temperature above the adjusted maximum value the display will
show for about 1 second.
[>TEST] for authorized service only,
[>POWER SET] congured power value,
- push knob to check a software version (PW...,MSP...),
- restore to factory settings [FACTORY SET] or to restart controllers [RESET],
- push and keep knob (for about 5sec., until the display show [--]) to up grate [FACTORY
SET] and [RESET] function,
[>EXIT] save a new parameter and menu exit.
Notice: parameters view mode will automatically exit (without saving changes) after 5
minutes since the last adjustment.
18 / 42 17 / 40 18 / 42

Other manuals for Kospel KDE3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kospel KDE3 and is the answer not in the manual?

Kospel KDE3 Specifications

General IconGeneral
BrandKospel
ModelKDE3
CategoryWater Heater
LanguageEnglish

Related product manuals