Input Voltage | AC 110V/220V; 50Hz/60Hz |
---|---|
Frequency | 50Hz/60Hz |
Output Voltage | 0-100V |
Output Current | 0-1A |
Display | 4-digital LED display |
Voltage Resolution | 10mV |
Current Resolution | 1mA |
Measurement Range | 0-100V, 0-1A |
Accuracy | ±0.1% + 5 digits |
Power Supply | AC 110V/220V; 50Hz/60Hz |
Operating Temperature | 0-40°C; Humidity: <80% |
Dimensions | 220 x 90 x 145mm |
Weight | 1.8kg |
Essential safety guidelines to prevent electric shock and personal injury during operation.
Identification and description of the physical controls and components on the device's front panel.
Details on the analog bar, primary display, and secondary screen of the digital insulation tester.
Explanation of various symbols displayed on the screen and their meaning for operation status.
Detailed explanations for indicators like low battery, lock, hold, compare, DAR, PI, timer, and memo functions.
Interpretation of messages shown on the primary and auxiliary displays, including battery status and function states.
Description of each button's active function for data storage, reading, timer, relative measurement, compare, and insulation test.
Details on the functions assigned to each position of the rotary switch, including OFF, DCV, ACV, Ohm/Continuity, and Insulation.
Identification and purpose of the input/output positive terminal and common terminals for different measurement modes.
How to activate special functions by holding buttons during power-on, such as disabling auto power-off or beep.
Explanation of the sleep mode for battery conservation and how to disable it.
Procedure to freeze the displayed value on the screen and how to release it.
How to perform relative measurements by setting a reference value and calculating the difference.
How to lock the insulation test function to maintain continuous measurement without holding the button.
Steps to save measurement data into memory, including selecting a memory code and confirming the save operation.
Instructions for deleting individual stored data entries or all memorized data from the device.
How to set upper and lower limits for comparison and interpret the PASS/FAIL indication.
How to activate and set the timer for insulation tests, including preset time adjustment.
How the meter records and allows viewing of maximum, minimum, and average measurement values.
Explanation of the Dielectric Absorption Ratio (DAR) and Polarization Index (PI) and their interpretation.
Step-by-step guide for measuring DC voltage using the appropriate rotary switch position and terminals.
Procedure for measuring AC voltage, including setting the rotary switch and connecting test leads.
Instructions for measuring resistance, emphasizing safety precautions and the continuity beeper function.