KPS-PF10 • Leakage clamp meter
ENG
6. SPECIFICATIONS
Accuracy is specied for a period of one year after calibration and at 18ºC to
28ºC(64°F to 82°F) with relative humidity to 75%.
GENERAL
DISPLAY: LCD, 1999 counts, updates 2 - 3/ sec.
OVERRANGE LNDICATION: “ 1 ” .
LOW BATTERY INDICATION: “
”.
POWER: DC1.5V×2 AAA
OPERATING ENVIRONMEMT: +5ºC to +35ºC
STORAGE TEMPERATURE: -10ºC to +50ºC
TEMPERATURE COEFFICIENT:
0.1×(Spec Acc’y) / ºC< 18ºC or >28ºC
JAW OPENING CAPABILITY: Φ 31mm,
DIMENSION: 176mm×59mm×28mm
WEIGHT: Approx. 150g
· Technical Parameters
AC CURRENT
Rango Resolución Precisión
200mA 0.1mA
± 2.0% ± 5 dig.2A 1mA
150A 0.1A
Frequency range: 60Hz.
Overload Protection: 120% ranges for 60 seconds max.
7. REPLACING THE BATTERY
WARNING
Replace only with same type of battery.
When the electrical tester displays the “ ” mark, the battery must be
replaced to avoid incorrect measuring data. Use the following procedure to
replacing the battery:
1. The power key is used to select “ O ” (OFF) .
2. Opening the battery cover by a piece coin.