Operating instructions
KRAL flowmeters.
Series OMG
OIO 14en-GB
Edition 2020-01
Original instructions
www.kral.at

Table of Contents

Questions and Answers

  • E
    Eric HoganAug 10, 2025
    What to do if my KRAL Measuring Instruments show no flow rate?
    • M
      marc14Aug 10, 2025
      If your KRAL Measuring Instruments indicate no flow rate, several factors could be at play. It could be due to foreign particles obstructing the liquid or the flowmeter itself—try dismantling and cleaning the flowmeter, or using a commissioning filter. Insufficient inlet pressure could also be the culprit, so try increasing it. Alternatively, the flow rate might be too low; in this case, increase the flow rate, consider using a flowmeter with a suitable size, or implement linearization, while observing the operating instructions of the electronic equipment. Conversely, if the flow rate is too high, reduce the flow or use a flowmeter with a suitable size. Finally, airlocks can cause this issue, so deaerate the system and inspect for leaks.
  • M
    Maureen ThompsonAug 15, 2025
    Why are my KRAL Measuring Instruments showing unrealistic measured values?
    • D
      dianahughesAug 16, 2025
      Unrealistic readings from your KRAL Measuring Instruments can stem from several causes. If the flow rate is too low, you can increase it, opt for a correctly sized flowmeter, or apply linearization, while observing the operating instructions of the electronic equipment. If the flow rate is too high, reduce it or choose a more appropriate flowmeter size. Airlocks can also lead to inaccurate measurements, so ensure you deaerate the system and check for any leaks.
  • D
    dakotabakerAug 21, 2025
    How to fix a leaking KRAL OMG-020 Measuring Instruments flowmeter?
    • V
      Victoria PageAug 21, 2025
      If your KRAL Measuring Instruments flowmeter is leaking, the cause might be a seal issue. It could be that the seal preload is too low, in which case you should preload the screws. Alternatively, the seal might be damaged, requiring you to replace it. Also, verify the chemical resistance of the seal to ensure it's appropriate for the application.
  • S
    Scott ConnerAug 27, 2025
    What to do if KRAL Measuring Instruments flowmeter does not generate a pulse?
    • D
      Dawn DavisAug 27, 2025
      If your KRAL Measuring Instruments flowmeter isn't generating a pulse, first check the pick-up connection and power supply, while observing the operating instructions of the pick up. If the connection is correct, the pick-up itself may be defective, so check its functionality, while observing the operating instructions of the pick up. Another potential cause is a destroyed dry sleeve, which would need to be replaced; contact the manufacturer for this.
  • T
    tony42Sep 3, 2025
    Why is there excessive pressure loss in KRAL Measuring Instruments?
    • D
      Denise HopkinsSep 3, 2025
      Excessive pressure loss in your KRAL Measuring Instruments could be due to the liquid's viscosity being too high. Try increasing the temperature, but be sure to stay within the specified temperature range.

Summary

Safety

Proper Use

Defines the correct and intended use of the flowmeter.

Foreseeable Misuse

Describes uses that are considered misuse of the product.

Identification

Fundamental Safety Instructions

Provides fundamental safety instructions that must be strictly observed.

Technical Data

Operating Limits

Specifies the permissible operating conditions for the flowmeter.

Pressure Bearing Capacity

OMG-013 Pressure Bearing Capacity

Shows pressure bearing capacity for the OMG-013 model.

OMG-020 Pressure Bearing Capacity

Shows pressure bearing capacity for the OMG-020 model.

OMG-032 Pressure Bearing Capacity

Shows pressure bearing capacity for the OMG-032 model.

OMG-052 Pressure Bearing Capacity

Shows pressure bearing capacity for the OMG-052 model.

OMG-068 Pressure Bearing Capacity

Shows pressure bearing capacity for the OMG-068 model.

OMG-100 Pressure Bearing Capacity

Shows pressure bearing capacity for the OMG-100 model.

OMG-140 Pressure Bearing Capacity

Shows pressure bearing capacity for the OMG-140 model.

Function Description

Signal Generation

Explains signal generation via pole wheel and pick-up, and K-factor.

Functional Principle

Explains how the flowmeter operates as a rotating displacement meter.

Transportation and Storage

Installation and Removal

Connection

Connecting to Pipe System

Details steps for connecting the flowmeter to the pipe system.

Operation

Maintenance

Maintaining Flowmeters

Lists signs of wear, causes, and elimination methods.

Servicing

Seals and Ball Bearings Replacement (OMG-020;032)

Details removal and installation of seals and ball bearings for OMG-020/032.

Seals and Ball Bearings Replacement (OMG-052;068)

Details removal and installation of seals and ball bearings for OMG-052/068.

Seals and Ball Bearings Replacement (OMG-100;140)

Details removal and installation of seals and ball bearings for OMG-100/140.

Seals and Ball Bearings Replacement (OMG-013)

Details removal and installation of seals and ball bearings for OMG-013.

Disposal

Dismantling and Disposing the Flowmeter

Provides steps and safety warnings for dismantling and disposing the flowmeter.

Troubleshooting

Possible Faults

Lists common faults and their potential causes.

Troubleshooting Steps

Provides remedies and steps to resolve identified faults.

KRAL OMG-020 Specifications

General IconGeneral
CategoryMeasuring Instruments
ModelOMG-020
ManufacturerKRAL
MaterialStainless Steel
Protection ClassIP65
Output Signal4-20 mA, Pulse
Power Supply24 VDC