Refrigerant | R410A, R134a, R407C |
---|---|
Pump Type | Centrifugal pump, Submersible pump |
Compressor Type | Scroll compressor, Semi-hermetic screw compressor |
Power Supply | 400V/3Ph/50Hz, 460V/3Ph/60Hz |
Protection Features | Overload protection, High/low pressure switches, Phase failure protection, Anti-freeze protection |
Inspect chiller for transport damages upon arrival and report any issues.
Unpack the unit completely and position it for installation.
Open panels using the key to find the instruction manual and wiring diagram.
Carefully read the entire instruction manual before proceeding.
Verify the chiller's voltage matches the local supply before connecting.
Tighten all cable connections inside the control cabinet for proper contact.
Set all circuit breakers to the ON position (1) for operation.
Install non-return valve and solenoid valve as per diagram for overflow protection.
Connect the solenoid valve cable to the specified clips in the control cabinet.
Connect the chiller to the water system, recommending an inlet strainer/filter.
Remove the cover of the buffer tank to access it for filling.
Fill the unit with water and check the level in the sight glass.
Add food-safe glycol for operation below +8°C or ambient temperatures below 0°C.
Bleed the pump by removing and retightening the bleed screw once medium exits.
Equip the machine with the correct local plug with appropriate amperage.
Measure and ensure the chiller is connected for correct clockwise rotation.
Close the control cabinet and turn on the main switch to start the chiller operation.
Check pump pressure capacity and ensure water system compatibility.
Adjust the pump pressure using the differential pressure switch as per manual.
Overview of the Carel IR32 controller display, buttons, and functions.
Information on pre-set switching stages and display indications for the controller.
Guide to setting the temperature set-points (ST1, ST2) for the medium.
Table of error indications, causes, and corrections for the Carel IR32 controller.
Overview of the Carel IR33 controller display, buttons, and functions.
Information on pre-set switching stages and display indications for the controller.
Guide to setting the temperature set-points (ST1, ST2) for the medium.
Table of error indications, causes, and corrections for the Carel IR33 controller.
Instructions on how to enter, navigate, and exit the 'Displaying inputs' menu.
Procedure for switching the Eliwell SMP5500 controller ON and OFF.
Operating the pump in inching mode using the Down-key.
Understanding the normal display and adjusting set-points using fixed value control.
Switching between heating/cooling and self-optimizing PID parameters.
Procedure to clear errors by pressing UP and Down keys simultaneously.