KREYER Chilly User Manual

KREYER Chilly
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Picture guide
Start-up of chillers type
Chilly
230V / single phase
Important notes:
The following picture guide is additional information to the official instruction manual and does
not replace it. The instructions in the manual are to be considered before this document.
Electrical and water installation and the start-up should be done by qualified personnel
Question and Answer IconNeed help?

Do you have a question about the KREYER Chilly and is the answer not in the manual?

KREYER Chilly Specifications

General IconGeneral
BrandKREYER
ModelChilly
CategoryChiller
LanguageEnglish

Summary

Chilly Unit Installation and Preparation

Unpacking and Initial Inspection

Inspect the unit for transport damage upon arrival and unpack carefully.

Location and Environmental Requirements

Select a suitable installation site with adequate ventilation and protection from elements.

Water System Setup and Configuration

Filling the Tank and Adding Glycol

Add clear water and then food-safe glycol to the tank for freeze protection.

Connecting Water Hoses

Connect the system water pipes/hoses to the chiller's inlet and outlet.

Bleeding Air from the Pump

Remove air from the pump by opening the water outlet valve until a constant flow is achieved.

Electrical Connection and Power-Up

Connecting the Power Supply

Connect the unit to the appropriate power supply, adapting the plug if necessary.

Ensuring Correct Lid Closure for Operation

Close the unit lid during operation for proper cold air transfer.

Switching the Unit On

Turn the main switch to the ON position to start the unit.

Temperature Control and Regulator Settings

Adjusting the Set Temperature

Set the desired cooling temperature using the controller interface.

PJ Easy Regulator Configuration

Configure the PJ Easy regulator, including switching between Celsius and Fahrenheit.

ELIWELL ST 120 Regulator Configuration

Operate and configure the ELIWELL ST 120 temperature regulator.

ELIWELL ST 120 °C/°F Unit Conversion

Change the temperature display unit for the ELIWELL ST 120 regulator.

Optional Features and Advanced Setup

Overflow Protection Kit Installation

Install the optional overflow protection kit for open water systems.

Differential Pressure Switch Adjustment

Adjust the differential pressure switch for proper pump operation.