2 SPECIAL CONDITIONS
26
OPTIMASS / 400
www.krohne.com 10/2022 - 4003491806- AD OPTIMASS 400 Atex R06 en
2.5.13 OPTIMASS 7000F / 7400C
OPTIMASS 7000F
OPTIMASS 7400C with aluminium converter housing
VE ab c...m n p...w
11...47 1 or 2
Ambient temp. T
amb
°C Max. medium temp. T
m
°C
Temp. class Max. Surface temp. °C
-40...+55 150 T3 - T1 T165
-40...+60 145 T3 - T1 T155
-40...+65 70 T6 - T1 T80
85 T5 - T1 T95
120 T4 - T1 T130
130 T3 - T1 T140
Minimum medium temperature: T
amb
-35°C T
m
= -50°C, T
amb
<-35°C T
m
= -40°C
VE ab c...m n p...w
11...47 0
Ambient temp. T
amb
°C Max. medium temp. T
m
°C
Temp. class Max. Surface temp. °C
-40...+50 150 T3 - T1 T165
-40...+55 115 T4 - T1 T130
120 T3 - T1 T135
-40...+60 80 T5 - T1 T95
90 T4 - T1 T105
-40...+65 65 T6 - T1 T80
Minimum medium temperature: T
amb
-35°C T
m
= -50°C, T
amb
<-35°C T
m
= -40°C