Main burner ON/OFF, pilot switches off automatically after main burner starts.
Main burner ON/OFF, pilot and main burners operate simultaneously.
Continuous main burner control via air valve for capacity.
Flame control by temperature, standard monitoring below 750°C.
Compliance for systems up to SIL 3 per EN 61508.
Compliance with Gas Appliances, Low Voltage, and EMC directives.
Describes the normal start-up sequence of the PFU 780.
Lists program statuses and corresponding fault messages.
How to view parameters using the unit's display and buttons.
Details on flame detection, signal processing, and thresholds.
Describes operating modes for pilot and main burner monitoring.
Unit behaviour during start-up and standby phases.
Details burner behaviour during various start-up steps.
Describes unit behaviour during normal operation and fault conditions.
Controls air valve functions for PFU..L models.
Procedures for setting and analysing faults in manual mode.
Protects parameter settings with a password.
How safety interlocks affect operation and faults.
Procedures for emergency stop situations.
High temperature operation using DI input for indirect flame control.
SIL rating, diagnostic coverage, failure probabilities, SFF.
Main burner ON/OFF, pilot switches off automatically after main burner starts.
Main burner ON/OFF, pilot and main burners operate simultaneously.
Continuous main burner control via air valve for capacity.
Flame control by temperature, standard monitoring below 750°C.
Compliance for systems up to SIL 3 per EN 61508.
Compliance with Gas Appliances, Low Voltage, and EMC directives.
Describes the normal start-up sequence of the PFU 780.
Lists program statuses and corresponding fault messages.
How to view parameters using the unit's display and buttons.
Details on flame detection, signal processing, and thresholds.
Describes operating modes for pilot and main burner monitoring.
Unit behaviour during start-up and standby phases.
Details burner behaviour during various start-up steps.
Describes unit behaviour during normal operation and fault conditions.
Controls air valve functions for PFU..L models.
Procedures for setting and analysing faults in manual mode.
Protects parameter settings with a password.
How safety interlocks affect operation and faults.
Procedures for emergency stop situations.
High temperature operation using DI input for indirect flame control.
SIL rating, diagnostic coverage, failure probabilities, SFF.
| Mains Voltage | 220-240 V AC |
|---|---|
| Mains Frequency | 50/60 Hz |
| Gas Valve Control | 24 V DC |
| Input Voltage | 230 V AC |
| Frequency | 50/60 Hz |
| Storage Temperature | -20 to +70 °C |
| Weight | 0.3 kg |