6 Commissioning/Start-up/Shutdown
36 of 68
Movitec
1798.82/11-EN
The pump set is removed from the piping and stored
ü The checks and maintenance operations have been performed.
1. Spray-coat the inside wall of the pump casing with a preservative.
2. Spray the preservative through the inlet and outlet nozzles of the fluid handled.
It is advisable to close the fluid inlet and outlet nozzles afterwards (e.g. with
plastic caps or similar).
Observe any additional instructions and information provided. (ðSection3,Page11)
6.4 Returning to service
For returning the equipment to service observe the sections on commissioning/start-
up and the operating limits. (ðSection6.1,Page29)
In addition, carry out all servicing/maintenance operations before returning the
pump (set) to service. (ðSection7,Page37)
WARNING
Failure to re-install or re-activate protective devices
Risk of injury from moving parts or escaping fluid!
As soon as the work is completed, properly re-install and re-activate any safety-
relevant devices and protective devices.
NOTE
If the equipment has been out of service for more than one year, replace all
elastomer seals.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KSB Movitec VSF 40/10-2 B and is the answer not in the manual?

KSB Movitec VSF 40/10-2 B Specifications

General IconGeneral
BrandKSB
ModelMovitec VSF 40/10-2 B
CategoryWater Pump
LanguageEnglish

Related product manuals