12
KTM | DEFCOM 3.1B User Manual
DISARM
OK
x1 x3 x2 x1 x2
ALARM
IN ACTIVE
PHASE
(AFTER 26 SEC.)
OVERRIDE”
EMERGENCY CODE
2 SEC.
3 QUICK
FLASHES
CONFIRM
3 QUICK
FLASHES
CONFIRM
3 QUICK
FLASHES
CONFIRM
( WITHIN 2 SEC. )
WITHIN 10 SEC. WITHIN 10 SEC. WITHIN 10 SEC. WITHIN 10 SEC.
WARNING: If 3 attempts to insert the wrong code are detected, the central unit will be blocked
for 10 minutes in order to prevent attempts to search for the code.
This product has one timed operation to protect the vehicle battery (STOP MODE) and an addi-
tional system to fast shut o if the battery voltage level goes down than 10,5V.
14. SYSTEM TO PREVENT VEHICLE BATTERY DISCHARGE
The alarm system automatically switches o in order to limit the consumption of current in the
motorcycles battery, automatically excluding the alarm functions but maintaining the immo-
bilization of the engine: in this condition current consumption is nil.
STOP MODE is activated 5 days after the system was armed last time if no alarms were trigge-
red in this time or if the motorcycle’s battery is almost  at (battery voltage level under 10,5V).
To exit from STOP MODE, turn the ignition key ON: the siren will emit a series of BEEP sounds;
Press the CARD B9.5 button within 20 seconds to disarm the alarm system.
If the CARD B9.5 button is not pressed within 20 seconds, an alarm cycle for ignition key sen-
sing will be triggered.
15. STOP MODE
If a CARD B9.5 is lost, stolen or damaged, it is possible to disarm the alarm system with a 5 digit
emergency code called the OVERRIDE’ CODE and this code is found on the label applied on
the alarm central unit body and is isn’t changeable.
Remove the label from the alarm unit body and keep it with you to be used if you needs it; keep
the OVERRIDE’ CODE in a safe place and not with the motorcycle.
The procedure is operational only after the initial immunity phase is over, and if the alarm fun-
ctions are operational, alarm cycles will be triggered while the override code is inserted.
Perform the following procedure.
With armed alarm system activate the instrument panel and immediately deactivate it; the LED
will turn ON, turn o and then start to  ash after 2 seconds.
16. OVERRIDE’ EMERGENCY CODE (PIN CODE)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KTM META SYSTEM DEFCOM 3.1B and is the answer not in the manual?

KTM META SYSTEM DEFCOM 3.1B Specifications

General IconGeneral
BrandKTM
ModelMETA SYSTEM DEFCOM 3.1B
CategoryMotorcycle Accessories
LanguageEnglish

Related product manuals