The control unit is normally paired with 2 B9.5 CARDs, to add other B9.5 CARDs or exclude its
from the control unit memory it is necessary to contact an installation center equipped with the
PRG007 programmer or use the smartphone App.
17. ADDITIONAL CARDS B9.5
Power supply .......................................................................................................12Vcc (10V-15V)
Consumption .........................................................................................................................2,1 mA
Consumption in STOP MODE ........................................................................................ 0,02 mA
Operating temperature ..........................................................................................- 25°C + 85°C
Sound level of siren ................................................................................................(1 mt.) 114 dB
Self-supply autonomy ...................................................................................................5 minutes
Sensitivity of internal movement sensor .....................................................1,5° per second
Frequency of Mycro remote control .....................................................................433.92 MHz
Frequency of CARD B9.5 .................................................................................................2.45 GHz
EMERGENCY ‘OVERRIDE’ CODE to reset immobilizer and alarm functions
18. SPECIFICATIONS
Starter motor relay ......................................................................................................................10A
Direction indicator relay ....................................................................................................5A + 5A
Horn control .....................................................................................Negative electronic 300mA
19. CAPACTITY OF CONTROLS
Initial immunity phase ...............................................................................................26 seconds
Duration of alarm cycle ...............................................................................................26 seconds
Interval between alarm cycles .....................................................................................5 seconds
Passive arming delay ...................................................................................................20 seconds
STOP MODE delay ...................................................................................................................5 days
Intermittence of direction indicators ................................................0,4 sec. O /0,4 sec. On
20. TIMING
Contact alarm inputs ........................................................................................................10 cycles
Tilt sensor .............................................................................................................................10 cycles
Ignition sensing .................................................................................................................10 cycles
Cable tampering ..................................................................................................................9 cycles
21. ALARM CYCLES