EasyManua.ls Logo

Kubler codix 130 - Input Specifications and Wiring; DC Input Specification; AC Input Specification; Screw Terminal Functions

Kubler codix 130
6 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LCD Display counter CODIX 132
• Low-price and high efficiency
• Large 8-digit LCD display, height of the
figures 8 mm [0.315”]
• Optional backlighting
• Counting mode up /down,
• High voltage input for 10 ... 260 V AC/DC
voltage pulses
• Unified Codix design, matches
the extensive Codix family
• IP 65
• Screw terminals, RM 5 mm [0.197“]
• Lifetime of the battery
approximately 8 years
• Locking of the reset key
• Ambient temperature
–10 ... +60 °C
[14 ... 140 °F]
• All versions for positive or negative
counting edge
• Filter function for bounce-free counting
with mechanical contacts.
Technical data:
Power supply: non-replaceable lithium battery
(lifetime approximately 8 years at 20 °C [68 °F])
Backlighting: external electrical source
24 V DC +/-20 %, 50 mA
Display: LCD, 8 digits, height of the figures 8 mm [0.315]
Mode: adding or subtracting (selectable)
counting direction
differential counting or
phase discriminator single or
dual evaluation, selectable
Display range: –9999999 ... 99999999, with overflow display
Reset: manual and electrical
UL certified: File: E128604
Interference emissions: EN 55011 Class B, EN 61000-6-2
EN 61010 Section 1 (only AC versions)
Housing: dark grey RAL 7021
Operating temperature: –10 ... +55 °C [14 ... 131 °F]
Ambient temperature: –10 ... +60 °C [14 ... 140 °F]
Storage temperature: –20 ... +70 °C [–4 ... 158 °F]
Protection: IP 65 front side
Weight: approx. 50 g [1.764 oz]
Counting inputs:
Counting input of the high voltage versions (10 ... 260 V DC/V AC)
Counting input: Optocoupler input, max. 30 Hz
Min. pulse time: 16 ms
Switching level: Low: 0 ... 2 V DC/V AC, High: 10 ... 260 V DC/V AC
Reset Input (only DC and high voltage)
Minimum pulse time: DC: 50 ms, high voltage: 16 ms
Contact input DC: NPN: Low: 0 ... 0.7 V, High: 3 ... 30 V DC
High voltage input: 10 ... 260 V DC/V AC
Electrical reset key locking (for DC and AC)
Contact input: Open Collector NPN (switching at 0 V)
Switching level: NPN: Low: 0 ... 0.7 V, High: 3 ... 5 V DC
Display counter electronic
max.5VDC
(-) BL
(+) BL
INP A
INP B
GND
1
3
2
4
5
6
7
8
Reset
Reset
Enable
10 .. 260
10 .. 260
VAC/VDC
VAC/VDC
Common
AC/DC
24 V DC ±20 %, 50 mA
AC type:
6.132.012.8x3
BL = backlight
Connection diagram:
RoHS
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com