LCD Display counter CODIX 132
Low-price and high efficiency
Large 8-digit LCD display, height of the
figures 8 mm [0.315”]
Optional backlighting
Counting mode up /down,
High voltage input for 10 ... 260 V AC/DC
voltage pulses
Unified Codix design, matches
the extensive Codix family
IP 65
Screw terminals, RM 5 mm [0.197“]
Lifetime of the battery
approximately 8 years
Locking of the reset key
Ambient temperature
10 ... +60 °C
[14 ... 140 °F]
All versions for positive or negative
counting edge
Filter function for bounce-free counting
with mechanical contacts.
Technical data:
Power supply: non-replaceable lithium battery
(lifetime approximately 8 years at 20 °C [68 °F])
Backlighting: external electrical source
24 V DC +/-20 %, 50 mA
Display: LCD, 8 digits, height of the figures 8 mm [0.315]
Mode: adding or subtracting (selectable)
counting direction
differential counting or
phase discriminator single or
dual evaluation, selectable
Display range: –9999999 ... 99999999, with overflow display
Reset: manual and electrical
UL certified: File: E128604
Interference emissions: EN 55011 Class B, EN 61000-6-2
EN 61010 Section 1 (only AC versions)
Housing: dark grey RAL 7021
Operating temperature: –10 ... +55 °C [14 ... 131 °F]
Ambient temperature: –10 ... +60 °C [14 ... 140 °F]
Storage temperature: –20 ... +70 °C [–4 ... 158 °F]
Protection: IP 65 front side
Weight: approx. 50 g [1.764 oz]
Counting inputs:
Counting input of the high voltage versions (10 ... 260 V DC/V AC)
Counting input: Optocoupler input, max. 30 Hz
Min. pulse time: 16 ms
Switching level: Low: 0 ... 2 V DC/V AC, High: 10 ... 260 V DC/V AC
Reset Input (only DC and high voltage)
Minimum pulse time: DC: 50 ms, high voltage: 16 ms
Contact input DC: NPN: Low: 0 ... 0.7 V, High: 3 ... 30 V DC
High voltage input: 10 ... 260 V DC/V AC
Electrical reset key locking (for DC and AC)
Contact input: Open Collector NPN (switching at 0 V)
Switching level: NPN: Low: 0 ... 0.7 V, High: 3 ... 5 V DC
Display counter electronic
max.5VDC
(-) BL
(+) BL
INP A
INP B
GND
1
3
2
4
5
6
7
8
Reset
Reset
Enable
10 .. 260
10 .. 260
VAC/VDC
VAC/VDC
Common
AC/DC
24 V DC ±20 %, 50 mA
AC type:
6.132.012.8x3
BL = backlight
Connection diagram:
RoHS