Only connect the device to the
electricity networks provided to
that purpose.
The safety of the system in which
the device is integrated is the
responsibility of the installer.
Disconnect all electricity networks
prior to any installation or mainte-
nance work.
Use exclusively cables approved
in your country and designed
for your temperature and power
ranges.
Installation and service work shall
be carried out exclusively by
qualified personnel.
The device must compulsorily be
protected with approved external
fuses. The value of these fuses
can be found in the technical
information.
This symbol is used on the de-
vice to remind of the existence of
dangers, which are referred to in
this manual.
2.1 Use according to the intended purpose
The counter detects and measures pulses,
times and frequencies up to max. 60 kHz and
offers a wide variety of different operating
modes. Use for any purpose over and beyond
this will be deemed as not in accordance with
its intended purpose and thus not complying
with the requirements.
The application area for this device lies in
industrial processes and controls, in the fields
of manufacturing lines for the metal, wood,
plastics, paper, glass, textile and other like
industries. Over-voltages at the terminals of
the device must be kept within the limits of
over-voltage Category II.
The device must only be operated when
mounted in a panel in the correct way and in
accordance with the section “Technical Data”.
Operating instructions
Electronic display counter
CODIX 541, 542, 543 and 544
1. Description
CODIX 541
Please note: Read first chapter 1-4 of CODIX
544 and go on on page 4.
CODIX 542
Please note: Read first chapter 1-4 of CODIX
544 and go on on page 6.
CODIX 543
Please note: Read first chapter 1-4 of CODIX
544 and go on on page 7.
CODIX 544
CODIX 544 is a multipurpose device. Depend-
ing on the programmed basic function, the
device operates like
• the pulse counter CODIX 541 (see page 4) or
the frequency meter CODIX 542 (see page 6) or
• the time meter CODIX 543 (see page 7)
1.1. Preface
Please read this instruction man-
ual entirely and carefully before
installation and start-up. Please
observe all warnings and advice,
both for your own safety and for
general plant safety. If the device
is not used in accordance with
this instruction manual, then
the intended protection can be
impaired.
2. Safety Instructions and Warnings
Please use the device only if its
technical condition is perfect. It
should be used only for its intend-
ed purpose. Please bear in mind
safety aspects and potential dan-
gers and adhere to the operating
instructions at all times.
Defective or damaged devices
should be disconnected from the
mains immediately and taken out
of operation.
The device shall not be opened.
Use the repair service of the
manufacturer.
!
t
t
english
Question and Answer IconNeed help?

Do you have a question about the Kubler CODIX 541 and is the answer not in the manual?

Kubler CODIX 541 Specifications

General IconGeneral
BrandKubler
ModelCODIX 541
CategoryCash Counter
LanguageEnglish

Summary

Product Description and Overview

CODIX 541 Model

Description of the CODIX 541 model, referencing other chapters.

CODIX 542 Model

Description of the CODIX 542 model, referencing other chapters.

CODIX 543 Model

Description of the CODIX 543 model, referencing other chapters.

CODIX 544 Multipurpose Device

Description of the CODIX 544 as a multipurpose device operating as other models.

General Information and Safety

Preface and Important Advice

Instructions to read the manual carefully for safety and proper operation.

Safety Instructions and Warnings

Guidelines for safe device usage, condition, and handling.

Intended Use of the Device

Defines the purpose and application areas for the counter device.

Installation and Electrical Setup

Control Panel Mounting

Instructions and precautions for mounting the device in a control panel.

Electrical Installation Guidelines

Safety and procedural requirements for electrical connections.

Operation and Troubleshooting

Cleaning and Maintenance

Procedures for cleaning the device and its maintenance-free operation.

Device Start-up Checklist

Points to check before starting the device for correct operation.

Failure Diagnosis

Common failure possibilities and their causes for troubleshooting.

Parameter Setting and Programming

Setting Operating Parameters

Step-by-step guide for setting device operating parameters.

Programming Routine Overview

Introduction to the programming routine and model-specific continuations.

CODIX 541 Pulse Counter Description

Detailed description of the CODIX 541 pulse counter features.

CODIX 541 Inputs

Description of the input types for the CODIX 541 pulse counter.

CODIX 541 Programming Details

CODIX 541 Inputs Section

Details on input types for the CODIX 541 pulse counter.

CODIX 541 Optocoupler Output

Information regarding the optional optocoupler output for CODIX 541.

CODIX 541 Programming Routine

Parameters and order for programming the CODIX 541 device.

CODIX 541 Input Polarity

Settings for input polarity (NPN/PNP) on the CODIX 541.

CODIX 541 30 Hz Filter

Configuration of the 30 Hz filter for inputs INP A and INP B.

CODIX 541 Multiplying Factor

Setting the multiplying factor for count values on CODIX 541.

CODIX 541 Dividing Factor

Setting the dividing factor for count values on CODIX 541.

CODIX 541 Advanced Settings

CODIX 541 Decimal Point Settings

Defining the decimal point for displaying count values.

CODIX 541 Display Mode

Selecting the display mode for count values on CODIX 541.

CODIX 541 SET/RESET Mode

Configuration of SET/RESET key and input modes.

CODIX 541 SET Value

Setting the target value for SET/RESET operations.

CODIX 541 End of Programming

Options for exiting the programming routine and saving settings.

CODIX 542 Tachometer/Frequency Meter

CODIX 542 Description

Features and specifications of the CODIX 542 frequency meter.

CODIX 542 Inputs

Description of input types for the CODIX 542 frequency meter.

CODIX 542 Optocoupler Output

Information on the optional optocoupler output for CODIX 542.

CODIX 542 Programming Routine

Parameters and order for programming the CODIX 542 device.

CODIX 543 Time Meter

CODIX 543 Description

Features and specifications of the CODIX 543 time meter.

CODIX 543 Inputs

Description of input types for the CODIX 543 time meter.

CODIX 543 Input Polarity

Settings for input polarity (NPN/PNP) on the CODIX 543.

CODIX 543 30 Hz Filter

Configuration of the 30 Hz filter for inputs INP A and INP B.

CODIX 543 Multiplying Factor

Setting the multiplying factor for time measurement on CODIX 543.

CODIX 543 Dividing Factor

Setting the dividing factor for time measurement on CODIX 543.

CODIX 543 Decimal Point Settings

Defining the decimal point for displaying time values.

CODIX 543 Display Mode

Selecting the display mode for time units on CODIX 543.

CODIX 543 Max. Time to Wait

Setting the maximum time before '0' is displayed.

CODIX 543 End of Programming

Options for exiting the programming routine and saving settings.

CODIX 543 Programming Details

CODIX 543 Inputs Section

Details on input types for the CODIX 543 time meter.

CODIX 543 Input Mode

Configuring input modes for start/stop and gate functions.

CODIX 543 Operating Mode

Selecting the time unit for measurement (seconds, minutes, hours).

CODIX 543 Input Polarity

Settings for input polarity (NPN/PNP) on the CODIX 543.

CODIX 543 30 Hz Filter

Configuration of the 30 Hz filter for inputs INP A and INP B.

CODIX 543 Decimal Point

Defining the decimal point for displaying time values.

General Device Settings and Data

CODIX 543 SET/RESET Mode

Configuration of SET/RESET key and input modes for CODIX 543.

CODIX 543 SET Value

Setting the target value for SET/RESET operations on CODIX 543.

CODIX 543 End of Programming

Options for exiting the programming routine and saving settings.

Technical Data: Supply Voltage

Specifications for AC and DC power supply voltage.

Technical Data: CODIX 541 Frequency

Count frequency specifications for CODIX 541 under different power supplies.

Technical Data: DC Power Supply

Detailed specifications for DC power supply input levels.

Device Specifications and Data

CODIX 542 Frequency Measurement

Accuracy and measurement principles for CODIX 542 frequency measurement.

Optocoupler Output Specification

Details on the NPN optocoupler output characteristics.

Sensor Supply Voltage Details

Information on voltage output for external sensors.

Ambient and Storage Temperature

Operating and storage temperature ranges for the device.

Altitude and EMC Specifications

Altitude limits and EMC compliance details (noise emission/immunity).

Device Safety and Insulation

Safety design, protection class, and insulation types.

Application Area and Housing

Details on application area, pollution level, and housing dimensions.

Hardware and Order Information

Terminal Assignment X1

Pinout and connection details for the X1 terminal.

Terminal Assignment X2

Pinout and connection details for the X2 terminal.

Delivery Contents

List of items included in the product delivery.

Ordering Code Structure

Explanation of the ordering code and its configurable options.

Device Dimensions

Physical dimensions of the device in millimeters and inches.