PERIODIC SERVICE66
BChecking Coolant Level
To avoid personal injury or death:
A Do not remove radiator cap while coolant is
hot. When cool, slowly rotate cap to the first
stop and allow sufficient time for excess
pressure to escape before removing the cap
completely.
1. Check to see that the coolant level is between the
"FULL" and "LOW" marks of recovery tank.
2. When the coolant level drops due to evaporation, add
soft water only up to the full level.
In case of leakage, add anti-freeze and soft water in
the specified mixing ratio up to the full level.
(See "Flushing Cooling System and Changing
Coolant" in "EVERY 2 YEARS" in "PERIODIC
SERVICE" section.)
A If the radiator cap has to be removed, follow the
caution above and securely retighten the cap.
A Use clean, fresh soft water and anti-freeze to fill the
recovery tank.
A If water should leak, consult your local KUBOTA
Dealer.
BCleaning Evacuator Valve
Open the evacuator valve to get rid of large particles of
dust and dirt.
(1) Recovery tank (A) "FULL"
(B) "LOW"
(1) Evacuator valve