EasyManua.ls Logo

Kubota GL6000-STD - Page 15

Kubota GL6000-STD
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3SPECIFICATION
ENGLISH
GENERATOR
Model Unit
GL9000 GL11000
–STD –AUS –USA –USA-TM –STD
Design
Salient-pole, revolving-field AC generator (AVR system with separate and self-excitation brush)
Frequency Hz 50 60
Rated Output (COP)
kVA 8 10
kW 8 10
Rated Voltage V 220 240 120/240 110/220
Rated amperage A 36.4 33.3 83.3/41.7 90.9/45.5
Phase & Wire ø-W 1-2 1-3
Power Factor % 100
No. of Poles 2
Insulation Rotor coil: Class F, Stator coil: Class B
Voltage Regulation % 5 (No load to full load)
Type of Coupling Direct coupled
DIESEL ENGINE
Model D722
Design Vertical, water-cooled, 4-cycle diesel engine
No. of cylinders 3
Bore × stroke mm (in.) ø 67 × 68 (2.6 × 2.7)
Displacement L (cu. in.) 0.719 (43.9)
Engine speed rpm 3000 3600
Lubricating Oil API service class CD or higher
Oil capacity
L (U.S.gal.)
3.4 (0.90)
Coolant capacity
L (U.S.gal.)
4.1 (1.1)
SET
Fuel Diesel fuel No. 2 (ASTM D975)
Fuel consumption (at full load)
L (U.S.gal.)/h
3.3 (0.87) 4.1 (1.08)
Fuel tank capacity
L (U.S.gal.)
28 (7.4)
Continuous Operating Hours
hrs 8.5 7.0
Battery (V × Ah/5Hr) 55B24R (12V × 36Ah)
Starting System Electric
L × W × H mm (in.) 1281 × 618 × 698 (50.4 × 24.3 × 27.5)
Approx Net Wt. kg (lbs.) 295 (650)
Output
Terminal { ——{{
Receptacle {{{{{
Emergency Stop System In case of abnormal : Oil pressure, water temperature