G-14
GL6000, GL7000, GL9000, GL11000, WSM
G GENERAL
7. CHECK AND MAINTENANCE
[1] DAILY CHECK
Checking Engine Oil Level
CAUTION
Be sure to stop the engine before checking the engine oil
level.
1. Level the engine and check the oil level on the gauge (1).
2. If the level below the lower mark, add new engine oil to the upper
mark.
IMPORTANT
When using an oil of different maker or viscosity from the
previous one, drain an old oil.
Never mix two different type's of oil.
Use the proper SAE Engine oil according to ambient
temperatures.
Refer to "4. LUBRICANTS, FUEL AND COOLANT" (G-9).
W1021730
Checking Coolant Level
CAUTION
Do not remove the radiator cap while operating or
immediately after stopping. Otherwise, hot water will spout
out from the radiator. Wait for more than ten minutes to cool
the radiator, before opening the cap.
1. Remove the radiator cap and check to see that the coolant level
is just below the port.
2. If low, add coolant to the radiator.
3. Check the reserve tank (1) and keep the coolant level between
the “FULL” and “LOW” marks.
4. If low, add coolant to the reserve tank (1).
W1040218
(1) Gauge
(1) Reserve Tank
KiSC issued 05, 2015 A

Table of Contents