EasyManua.ls Logo

Kubota KF-C3000 - Calibration; Adjust;Maintenance Menu; Integrated Zero Adjustment

Kubota KF-C3000
6 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3. CALIBRATION
1) In operation screen, when you press key, below screen will display.
1-1) Integrated Zero Adjustment
It will start when belt is on
No-load state.
① Start belt in No-load state.
② When the belt operated at a steady rate,
press key , and Integrated Zero
adjustment start.
③ When it arrives a standard pulse, Controller
stop calculating automatically.
④ If you press the key after
calculating, integrated Zero value is inputted.
⑤ After doing once more ①~③ ,
when Integrated Zero value is in scope
of ±0.12%,
adjustment is finished.
press key to go former screen.
3/5