Display and Control Panel Buttons
In the Diagnostics menu, the display shows the currently selected test, test modes, actions, and
test results.
Press the Record and Play/Stop buttons to navigate through the available tests. To select a test,
press the Next button. Press the Record or Play/Stop button to select the Test Mode: Once,
Loop or Continuous. Then press the Next button to begin the test. While some tests are
processing, Running... scrolls across the LED display.
Some tests have additional test options. In this case, use the Record and Play/Stop buttons to
navigate through the available test options, press the Next button to choose the option and run
the test. To return to the previous menu or option, press the Previous button.
To return to the Boot Loader, press the Previous button.
Test Results
At the completion of an individual test, the display shows the results of the test; the test name
and OK for a passed test or ER for a failed test. When a test fails, additional lines of test results
may scroll across the display. Use the Record and Play/Stop buttons to review each line of test
results.
Diagnostic Test Modes
Run Once
The Run Once test mode allows you to select and run an individual test. With Run Once
selected in the display, press the Next button to select and run the test once.
At the completion of a test, whether pass or fail, press the Previous button to exit the test and
return to the Diagnostics menu.
To exit the Diagnostics menu, press the Previous button to return to the Boot Loader.
Loop
Loop continuously runs an individual test. The display continuously displays the number of
tests performed in the run eld (Run:#), and displays the number of failed tests performed in
the fail eld, (fail:#).
Loop stops if a failure is detected.
Continuous
Continuous is the same as Loop, but does not stop if a failure is detected. Continuous runs the
selected test until you press the Previous button.
Diagnostics
Entering Diagnostics
3-2