Replacing the Keyboard Contact Strips
1. Position the contact strip on the keyboard contact board that you are servicing.
Note: Be sure that the deeper indentation is positioned toward the rear of the key.
2. Line up the contact strip mounting pegs with their respective mounting holes on the
keyboard contact board.
3. Using a small blunt-end tool (Q-Tip, toothpick, etc.), gently push the mounting pegs
through the holes. Do not use too much force or use a tool that can poke a hole through the
mounting pegs. However, be sure that the mounting pegs are installed through the holes
and the contact strip is at against the keyboard contact board at each peg location.