Chapter
4
Troubleshooting
A
section
of
notes
dead
1;
4,
Remove
the
Contact
Board
that
relates
to
the
missing
section
of
notes.
Check
contacts
for
dirt,
damage
or
wearing.
If
dirty,
remove
debris,
clean
with
denatured
alcohol
and
reinstall.
Replace
contact
strip
if
damaged
or
worn.
If
problem
persists,
remove
strip
and
check
board
for
shorts,
cold
solder
joints
or
open
diodes.
If
necessary,
order
circuit
board
replacement.
Middle
C
Dead
1.
Check
small
interconnect
cable
that
connects
the
Bass
and
Treble
boards.
If
this
cable
is
disconnected
from
either
the
Treble
or
Bass
Contact
Boards,
Middle
C
will
not
sound.
However,
all
other
notes
should
play
normally.
Disconnect
and
reseat
it,
if
necessary.
Check
solder
connections.
If
Middle
C
is
still
dead,
remove
the
Treble
Contact
Board.
Check
the
contact
strip.
Make
sure
the
contact
is
seated
properly,
clean
and
clear
of
any
foreign
matter
on
both
sides
of
the
strip.
PC88
Service
Manual
4-11