EasyManua.ls Logo

La Crosse Technology WS-1613-IT User Manual

La Crosse Technology WS-1613-IT
10 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
PROFESSIONAL WEATHER CENTER
WS-1613-IT
Operation Manual
IMPORTANT:
When a battery change is required on any of the units of this set, ALL units
have to be reset and user must go through initial set-up steps again.
1
Table of Contents
Topic Page
Features 3
Setting up 6
Function keys 12
LCD Screen 14
Manual Setting 16
Time alarm setting 24
Weather alarm operations 25
Hysteresis 31
Weather forecast and weather tendency 32
Wind direction and wind speed measurement 36
Rainfall measurement 37
Viewing history data 37
Viewing the min/ max weather data 39
Switch On/ Off buzzer 46
Outdoor transmission 915 MHz reception 48
Positioning 49
Care and Maintenance 53
Specification 54
Warranty Info 56
2
PROFESSIONAL WEATHER CENTER
Instruction Manual
Congratulations on purchasing this state-of-the-art Professional Weather Center as an
example of excellent design and innovative technology. Featuring time, date,
calendar, weather forecast, wind direction and speed, rainfall, outdoor temperature
and outdoor humidity, air pressure and various alarm settings for different weather
conditions, this Weather Center will provide you with extensive weather information
and forecast.
INSTANT TRANSMISSION is the
state-of-the-art new wireless
transmission technology, exclusively
designed and developed by LA
CROSSE TECHNOLOGY. INSTANT
TRANSMISSION
offers you an
immediate update (every 4 seconds!)
of all your outdoor data measured
from the transmitters: follow your
climatic variations in real-time!
This
p
roduct offers:
3
FEATURES:
Weather Center
Time display (manual setting)
12/24 hour time display
Calendar display (weekday, date, month, year)
Time alarm function
Weather forecasting function with 3 weather icons and weather tendency
indicator
Outdoor temperature display in ºF/°C
Outdoor Humidity display as RH%
MIN/MAX value of outdoor temperature and humidity display with time & date of
recording
Function keys
LCD
Foldout stand
Battery compartment
cover
Hanging hole
4
Low/High outdoor temperature and humidity alarm
Relative air pressure displayed in inHg or hPa
Air pressure tendency indicator for the past 12 hours (bargraph format)
LCD contrast selectable
Low battery indicator
Wind direction displayed in 16 steps
Wind speed displayed in mph, km/h, or m/s, and Beaufort scale
Wind chill displayed in °F of °C
Max wind speed displayed with time & date of recording
High alarm function for wind speed
Manual reset of outdoor temperature/ humidity, pressure and wind chill data
Total rainfall displayed in mm or inch
Storm warning alarm
Buzzer on/off selectable
Storage of 200 sets of history weather data recorded in 3-hour intervals
Wireless transmission at 915 MHz
Transmission range up to 330 feet (100 meters)
Thermo-hygro Sensor
Remote transmission of the outdoor temperature and humidity
to the Weather Center at 915 MHz
Weather-resistant casing
Wall mounting case (to be mounted in a sheltered place. Avoid
direct rain and sunshine)
5
Wind Sensor
Connected to the thermo-hygro sensor by cable
Can be installed onto a mast or a horizontal panel
Rain Sensor
Connected to the thermo-hygro sensor by cable
To be mounted onto a horizontal panel
Question and Answer IconNeed help?

Do you have a question about the La Crosse Technology WS-1613-IT and is the answer not in the manual?

La Crosse Technology WS-1613-IT Specifications

Weather Center

Temperature and Humidity IconTemperature and Humidity
Outdoor temperature measuring range-40°F to +139.8°F with 0.2°F resolution, -40ºC to +59.9ºC with 0.1ºC resolution
Relative humidity measuring range1% to 99% with 1% resolution
Wind and Rain IconWind and Rain
Wind speed0 to 111.8 mph (0 to 50 m/s)
Wind chill-40°F to +139.8°F (-40ºC to +59.9ºC)
Rainfall0" to 393.6" (0 to 9999 mm)
Pressure IconPressure
Relative pressure pre-set range27.17 to 31.90 inHg (919 to 1080 hPa)
Air pressure checking intervalevery 15 seconds
Transmission rangeup to 330 feet (100 meters) in open space
Power and Dimensions IconPower and Dimensions
Power consumption - Weather Center3 x AA, IEC LR6, 1.5V
Battery lifeapproximately 24 months
Dimensions of Weather Station6.51" x 1.21" x 5.58" (165.4 x 30.8 x 141.9 mm)

Bonus Receiver

Temperature and Humidity IconTemperature and Humidity
Indoor temperature measuring range14.1°F to +139.8°F with 0.2°F resolution, -9.9ºC to +59.9ºC with 0.1ºC resolution
Outdoor temperature measuring range-39.8°F to +139.8°F with 0.2°F resolution
Power and Dimensions IconPower and Dimensions
Power consumption - Bonus Receiver2 x AA, IEC LR6, 1.5V
Battery life cycleapproximately 24 months
Dimensions of Bonus Receiver2.76” x 1.14” x 4.54” (70 x 29 x 115.2mm)

Summary

Features

Weather Center

Overview of the main weather monitoring unit and its components.

Wind Sensor

Details on the wind sensor component and its mounting.

Rain Sensor

Details on the rain sensor component and its mounting.

Thermo-hygro Sensor

Details on the outdoor sensor for temperature and humidity.

Setting Up

How to Install and Replace Batteries into the Thermo-hygro Sensor

Step-by-step guide for battery installation in the outdoor sensor.

How to Install and Replace Batteries into the Weather Center

Step-by-step guide for battery installation in the main unit.

How to Install and Replace Batteries into the Bonus Receiver

Step-by-step guide for battery installation in the bonus receiver.

Battery Change

Function Keys

SET Key

Function of the SET key for manual settings and confirmations.

+ Key

Function of the + key for adjusting settings and stopping alarms.

HISTORY Key

Function of the HISTORY key for viewing historical data.

ALARM Key

Function of the ALARM key for setting and managing alarms.

MIN/MAX Key

Function of the MIN/MAX key for viewing extreme data.

Manual Setting

LCD Contrast Setting

Adjusting the brightness and contrast of the LCD screen.

Manual Time Setting

Procedure for manually setting the current time.

12/24 Hour Time Display Setting

Configuring the time display format between 12-hour and 24-hour.

Calendar Setting

Procedure for manually setting the date, month, and year.

Temperature Unit Setting (°F/°C)

Selecting the preferred unit for temperature display.

Wind Speed Unit Setting

Selecting the preferred unit for wind speed display.

Rainfall Unit Setting

Selecting the preferred unit for rainfall measurement.

Air Pressure Unit Setting

Selecting the preferred unit for air pressure display.

Relative Pressure Reference Value Setting

Manually calibrating the barometric pressure reference.

Weather Tendency Sensitivity Level Setting

Adjusting the sensitivity for weather forecast icon changes.

Storm Warning Threshold Value Setting

Defining the pressure drop threshold for storm warnings.

Storm Alarm On/Off Setting

Enabling or disabling the audible storm warning alarm.

Time Alarm Setting

Weather Alarm Operations

High Outdoor Temperature Alarm

Setting and managing the high temperature alarm.

Low Outdoor Temperature Alarm

Setting and managing the low temperature alarm.

High Outdoor Humidity Alarm

Setting and managing the high humidity alarm.

Low Outdoor Humidity Alarm

Setting and managing the low humidity alarm.

Wind Speed Alarm Setting

Setting and managing the high wind speed alarm.

Hysteresis

Weather Forecast and Weather Tendency

Weather Forecasting Icons

Interpreting the icons used for weather forecasting.

Weather Tendency Indicator

Understanding the arrows indicating pressure change.

Air Pressure History

Wind Direction and Wind Speed Measurement

Rainfall Measurement

Viewing History Data

Viewing the Min/Max Weather Data

Reset the Min/Max Weather Data

Total Rainfall Amount

Switching On/Off the Buzzer

Low Battery Indicator

Outdoor Transmitter 915 MHz Reception

Positioning

Care and Maintenance

Specifications

Liability Disclaimer

Warranty

Related product manuals