EasyManua.ls Logo

La Spaziale Compact S9 - Alarm Manager - Ek Model

La Spaziale Compact S9
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
espresso coffee machines
48
8
9
-
LSI 089 - Rev. 00 - Ed. 04/2015
6. ALARM MANAGER – EK MODEL
This model communicates any anomalies through the relevant symbols on the touchpads.
1. SYMBOL CORRESPONDING TO THE COFFEE DOSE BUTTON ON DELIVERY MODE, FLASHING AFTER 5-6 SECONDS:
• Coffeegroundtoofinely.
• Missingreadingofthepulsessentbytheflowmetertothedispensinggroup.
2. ALL DOSE SYMBOLS ON ALL TOUCHPADS FLASHING AND TEMPERATURE SYMBOLS SWITCHED OFF:
• Theautomaticrefillsystemfortheboilerhasbeenoperatingforlongerthan3minutes(totalblockofallmachineoperations).To
restore normal operation, switch the machine off using the main switch.
If the problem occurs again, check the automatic refill system for the boiler.