44
SIDE TAMP ADJUSTMENT
Thetamppressureandflowcontrolsweresetatthefactory.Usethefollowinginstructionstocheckthe
tampfunctionandtomak eadjustmentsifnecessary.
1. Setthesidetampairpressureregulatorto60P.S.I.(4.0bar).
2.Disablethetamp.
3.FromtheAdvancedmenu,usethe[up/down]arrowstoselectsidetampextendtime.
4.Pressthe[FEED]keytocyclethesidetampseveraltimesandobservethetampaction.Theside
tamp
shouldmovequicklyandsmoothlywithoutslammingtoastopateitherendoftravel.
Ifthetampfunctionsproperly,leavethe[TAMP]INDisablemodeandpressthe[enter]bu tton.
Ifthetampdoesnotmovequicklyandsmoothly,orifitslamstoastopateither
endoftravel,continue
withstep5.
5.Locatethesidetampflowcontrolslocatedonthetampsupportassembly.
6.Loosenthesidetampflowcontrollocknutswitha 3/8inchopenendwrench.
7.Pressthe[feed]buttontocyclethesidetampand:
AAdjustthethumbscrew
ontheextendflowcontroluntilthesidetampextendsquickly,butdoesnot
crashtoastop;and
BAdjustthethumbscrewontheretractflowcontroluntilthesidetampretractsquickly,butdoesnot
crashtoastop.