7
SIDE TAMP EXTEND TIME‐AvailableonlywhenDUAL TAMP MODEissettoYES.Thistellsthe
microprocessortheamountoftimeinmillisecondsittakesthesidetamptomovefromthe
retractedpositiontotheextendedposition.ThisisrequiredfortheAirBlasttooccuratthe
righttime.Thisvaluecanbesetfrom1to3000milliseconds.
SIDE TAMP RETRACT TIME‐AvailableonlywhenDUAL TAMP MODEissettoYES.Thistellsthe
microprocessortheamountoftimeinmillisecondsittakesthesidetamptomovefromthe
extendedpositiontotheretractedposition.Thisisrequiredforthelabelfeedtobeginatthe
righttime.Thisvaluecanbesetfrom1to3000milliseconds.
SIDE TAMP AIR BLAST DWELL‐AvailableonlywhenDUAL TAMP MODEissettoYES.Thissets
thedurationoftheairblastforthesidetamp.Thisvaluecanbesetfrom1to999milliseconds.
INVERTED TAMP‐AvailableonlywhenDUAL TAMP MODEissettoNO.ThisissettoYESfor
InvertedTampBlowoperation,ortoNOforTampBlowoperation.
TAMP EXTEND TIME‐AvailableonlywhenDUAL TAMP MODEissettoNO.Thistellsthe
microprocessortheamountoftimeinmillisecondsittakesthetamptomovefromthe
retractedpositiontotheextendedposition.ThisisrequiredfortheAirBlasttooccuratthe
righttime.Thisvaluecanbesetfrom1to3000milliseconds.
TAMP RETRACT TIME‐AvailableonlywhenDUAL TAMP MODEissettoNO.Thistellsthe
microprocessortheamountoftimeinmillisecondsittakesthetamptomovefromthe
extendedpositiontotheretractedposition.Thisisrequiredforthelabelfeedtobeginatthe
righttime.Thisvaluecanbesetfrom1to3000milliseconds.
AIR BLAST DWELL‐AvailableonlywhenDUAL TAMP MODEissettoNO.Thissetstheduration
oftheairblast.Thisvaluecanbesetfrom 1to999milliseconds.
PRODUCT SENSOR EDGE‐ThiscanbesettoLEADINGorTRAILINGasdesired.LEADINGis
usuallypreferred.
PRODUCT DETECTED‐Thisinformationaldisplayindicateswethertheproductdetectoris
detectingaproductornot.ItcanbeYESorNO.
LABEL ON PRODUCT POSITION‐Thissetsthedelayindistancebetweenproductdetectionand
theapplicationofthelabel.Thisvaluecanbesetfrom1.00to40.00inches.
PRODUCT DETECTOR LOCKOUT‐Thisfunctionallowsyoutosetadistanceduringwhichthe
applicatorwillignoreanyproductinputs.Usethisfunctionwhentheproductdetectoris