Labgear TV Distribution System
LDU608G/LDU604G
Using a sharp knife carefully remove 20mm of the outer
plastic of the cable, ensuring not to cut the shield
braiding below. Take half the braiding to each side and
twist, creating two tails.
Remove the metal foil to expose the insulator below.
With your knife trim the insulator to about 2-3mm from
the base of the exposed cable, ensuring not to cut the
inner cable.
Ensure that none of the braids from the outer tails are
loose. Pull the tails down and twist them round the
outer insulator in a helter-skelter formation.
Twist the connector down so it bites onto the braiding
and outer insulator. Check that there is no connection
between the inner core and braiding and tighten until
the inner insulator is in line with the inside hole
Trim any excess braiding with a sharp knife and tightly
wrap round the edge with electrical insulation tape. For
outdoor use (ie satellite dish/masthead amp) it is
recommended that you dip the connector into
Vaseline/silicon grease for waterproofing.
How to fit an F-type connector
www.cyberselect.co.uk
01603 789840
Copyright CyberSelect Ltd 2014
Question and Answer IconNeed help?

Do you have a question about the Labgear LDU608G and is the answer not in the manual?

Labgear LDU608G Specifications

General IconGeneral
BrandLabgear
ModelLDU608G
CategoryAmplifier
LanguageEnglish

Summary

How to Fit an F-Type Connector

Prepare Outer Plastic and Braiding

Remove 20mm of outer plastic, split and twist the shield braiding into two tails.

Expose Insulator and Trim

Remove metal foil, trim insulator to 2-3mm from exposed cable, avoiding the inner cable.

Secure Braiding Formation

Twist tails around the outer insulator in a 'helter-skelter' formation, ensuring no loose braids.

Connect Connector and Check

Tighten connector onto braiding/insulator, check for shorts, and align inner insulator.

Trim Excess and Waterproof

Trim excess braiding, tape, and waterproof with grease for outdoor use.

Labgear TV Distribution System Overview

IR Control for Remote Rooms

Remote Equipment Control

Control centrally located equipment via coaxial cable using tvLINK or HandyLink.

HandyLink Box Placement

Place HandyLink box at main location before connecting back to the Up-Link.

IR Sensor Connection

Connect IR sensors to TV wall outlet before any other equipment.

Outlet Requirements

Must use non-isolated outlets for IR control functionality.

Distributing Cable TV Without Sky

Cable TV Feed

Run cable feed directly to the decoder for distribution, similar to Sky.

IR Control for Cable TV

Use HandyLink IR for control when distributing Cable TV.

Unit Switch Setting

Set unit switch to UHF & CCTV for TV pictures to remote locations.

Multi-Location Sky Decoder Configuration

Cable Requirements

Run four satellite grade CT100 aerial cables to each main location for multiple decoders.

System Control with tvLINKS

Control up to four Sky decoders using tvLINKS and the Global Super Plus Combiner.