EasyManua.ls Logo

Labgear LDL206LP User Manual

Labgear LDL206LP
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
LDL206LP - 6 Way Remote Powered Amplifier
LDL208LP - 8 Way Remote Powered Amplifier
(with DigiLink IR return paths)
For further information or any queries please contact
Customer Careline: 08457 573 479
(Local rate – UK only)
Technical Support: www.philex.com/support
2 –Year Guarantee
Your amplier is guaranteed against faulty components or poor workmanship for a
period of two years from the date of purchase.
This guarantee does not cover accidental or malicious damage (Including damage from
natural causes such as lightening) and will be invalidated by installation or use other
than in accordance with these instructions, repair or attempted repair other than by the
manufacturer, or open or removal of the case. This does aect your statutory rights.
Labgear Reserve the right to modify their designs or specications, In the light of future
developments, without prior notice. Performance gures quoted are typical and subject
to normal manufacturing and service tolerances
Installation Instructions
Introduction
These fully screened 6 and 8 way TV and FM/DAB
ampliers are line powered by the separate PSUF
power unit supplied. This allows the ampliers to be
positioned anywhere in the building as long as they
are connected with good quality coax cable to the
power unit. This makes them ideal for installation in
lofts where no 13 Amp power supply is available.
The ampliers have IR return paths on all outlets making them fully
compatible with Labgear DigiLink and other similar remote control systems.
This makes them perfect for use in digital satellite home
installations, where the output from a digibox™ can be
distributed to several rooms with the capability for full
remote control of the digibox™ in these rooms.
The addition of a number of MRX955 DigiLink remote
eyes in the relevant rooms completes the installation.
Alternatively the products may be used as traditional distribution
ampliers without making use of the infra red capability.
Separate inputs are provided for UHF TV (470-790 MHz) and for FM/DAB (47-300 MHz).
Remote capability is provided over a 5-15 MHz RF return path.
All amplier outputs are line powered at 9V DC to supply remote infra-red receivers. The line power
at any output(s) can be short-circuited safely, without aecting the operation of any other output(s).
Both units are also suitable for direct amplication of digital terrestrial TV (Freeview™) signals and
the UHF input can be connected directly to a UHF antenna instead of a satellite receiver.
When connected directly to a UHF aerial the integrated lter will remove any signals from Lte 800 4G
mobile phone transmitters picked up by the attached aerial.
Please Note: These ampliers are NOT COMPATIBLE with the Labgear Handylink Remote control
extender system (MRX120). These ampliers do not provide line-power for masthead preampliers.
Applications
Applications include the following:
Simple multipoint distribution of radio and TV signals, without remote control.
This will allow quick and easy addition of an IR control at a later date;
Use in conjunction with a Sky Digibox™ or other unit with an IR-return enabled RF output.
An MRX955 DigiLink room kit will be required for each room from which remote control
is needed (because the Digibox can decode the IR return signals directly, this application
does not require any base unit or IR re-emitters).
Example application diagram is shown on page 2.
Please Note: when using these amplifiers with a Sky Digibox, the amplifier must be fed from
RF OUT-2 socket of the Digibox. However if the RF Channel is set to 61 or above (68 is usually
the default channel) you will need to reset it to a channel from 21-60 in the Digibox Setup
Menu (see bottom of page 3). Later Digibox models such as the Sky+HD 2TB are not fitted
with an RF OUT2 output and you will need an I/O link to distribute signals from the Digibox
to other TVs.
To view satellite RF2 output TVs require an analogue tuner.
General Safety Precautions
To Prevent Overheating
The recommended clearances and other precautions given in these instructions must be
observed to prevent overheating. In addition, units should not be positioned where they
are likely to become covered by curtains/fabrics or thermal insulation materials in a roof
space or similar building void. The unit should not be left resting on a carpet.
Other Precautions
These appliances are not waterproof. They are for indoor use only and must not be posi-
tioned where they could be exposed to dripping or splashing water. Objects containing
liquids should not be placed on or near the appliance. To prevent risk of re, keep the
unit and attached wiring well away from naked ames.
Fitted Mains Plug
These power supplies are tted with a standard xed plug. If this is not suitable, refer
to the instructions below. If you need to change the fuse in this plug, a 3 Amp fuse to
BS1362 carrying the ASTA or BSI approved mark must be used.
Always re-t the plastic fuse carrier when replacing the fuse.
Changing the Plug
If the tted mains plug is not suitable for the socket outlet in use, it should be cut o
and an appropriate new plug tted. Any instruction supplied with the plug should be
followed. The Brown wire must be connected to the live (L) terminal of the plug and the
Blue wire to the neutral (N) terminal. Neither wire should be connected to the earth (E)
terminal of a 3-pin plug (this appliance does not require an earth connection). Ensure
that the cord grip in the plug is correctly used and clamps the sheath of the cord rmly.
Fuse Rating: If the new plug is a fused type, the fuse tted should be rated at no more
than 3 Amp. Caution: The old plug should be disposed of promptly since it would be
dangerous if plugged into a live socket.
1
Installation Instructions
Lte
800
READY
Waste electrical products should not
be disposed of with household waste.
Please recycle where facilities exist.
Check with your Local Authority for
recycling advice.
© Philex Electronic Ltd. 2014 V1.2
4
Question and Answer IconNeed help?

Do you have a question about the Labgear LDL206LP and is the answer not in the manual?

Labgear LDL206LP Specifications

General IconGeneral
BrandLabgear
ModelLDL206LP
CategoryAmplifier
LanguageEnglish

Summary

General Safety Precautions

To Prevent Overheating

Precautions to prevent overheating, including clearances and avoiding covering the unit with materials.

Other Precautions

Warnings about water exposure, liquids, and keeping away from naked flames.

Fitted Mains Plug

Information on the standard fitted plug, fuse rating, and replacement.

Changing the Plug

Instructions for changing the mains plug, including wiring and fuse rating.

2-Year Guarantee

Details of the 2-year guarantee, exclusions, and manufacturer's rights.

Installation Instructions

Introduction

Overview of the 6 and 8 way amplifiers, their power source, and DigiLink compatibility.

Applications

Use cases for the amplifiers, including distribution and remote control of digiboxes.

Location

Guidance on choosing a suitable location for the amplifier, considering ventilation and access.

Fixing

Instructions on how to fix the amplifier to a wall or suitable surface securely.

Electricity Supply

Details on connecting the amplifier to the mains electricity supply and fuse requirements.

Signal Connections

Information on using F type connectors for input and output signal connections.

Resetting RF Channel on a Digibox

Step-by-step guide to resetting the RF channel on a Sky Digibox for compatibility.

Related product manuals