INSTALLATION AND SERVICE MANUAL
FOR
FLAVOR SELECT 30 (FS30)
ICE BEVERAGE DISPENSER
LANCER SERIES 14800
DATE: 03/06/06
P.N. 28–0558/02
This manual supersedes and replaces 28-0558/01, dated 03/17/05.
FAX Engineering: 210-310-7096
"Lancer" is the registered trademark of Lancer Copyright — 2006 by Lancer, all rights reserved
6655 LANCER BLVD. • SAN ANTONIO, TEXAS 78219 USA • (210) 310-7000
FAX SALES
• NORTH AMERICA – 210-310-7245 • INTERNATIONAL SALES – 210-310-7242 • CUSTOMER SERVICE – 210-310-7242 •
• LATIN AMERICA – 210-310-7245 • EUROPE – 32-2-755-2399 • PACIFIC – 61-8-8268-1978 •
85-14808-12 ICE BEVERAGE DISPENSER, ABOVE COUNTER MULTI BRAND,
30 INCH WIDE, 8 BRANDS / 12 FLAVORS, 115V/60Hz
85-14808N-12 ICE BEVERAGE DISPENSER, ABOVE COUNTER MULTI BRAND, PELLET ICE
30 INCH WIDE, 8 BRANDS / 12 FLAVORS, 115V/60Hz
85-14810-12 ICE BEVERAGE DISPENSER, ABOVE COUNTER MULTI BRAND,
30 INCH WIDE, 10 BRANDS / 12 FLAVORS, 115V/60Hz
85-14810N-12 ICE BEVERAGE DISPENSER, ABOVE COUNTER MULTI BRAND, PELLET ICE
30 INCH WIDE, 10 BRANDS / 12 FLAVORS, 115V/60Hz
85-14812-12 ICE BEVERAGE DISPENSER, ABOVE COUNTER MULTI BRAND,
30 INCH WIDE, 12 BRANDS / 12 FLAVORS, 115V/60Hz
85-14812N-12 ICE BEVERAGE DISPENSER, ABOVE COUNTER MULTI BRAND, PELLET ICE
30 INCH WIDE, 12 BRANDS / 12 FLAVORS, 115V/60Hz
85-14814-12 ICE BEVERAGE DISPENSER, ABOVE COUNTER MULTI BRAND,
30 INCH WIDE, 14 BRANDS / 12 FLAVORS, 115V/60Hz
85-14814N-12 ICE BEVERAGE DISPENSER, ABOVE COUNTER MULTI BRAND, PELLET ICE
30 INCH WIDE, 14 BRANDS / 12 FLAVORS, 115V/60Hz
85-14816-12 ICE BEVERAGE DISPENSER, ABOVE COUNTER MULTI BRAND,
30 INCH WIDE, 16 BRANDS / 12 FLAVORS, 115V/60Hz
85-14816N-12 ICE BEVERAGE DISPENSER, ABOVE COUNTER MULTI BRAND, PELLET ICE
30 INCH WIDE, 16 BRANDS / 12 FLAVORS, 115V/60Hz

Questions and Answers

  • J
    jeffreysmithSep 23, 2025
    Why is the carbonator pump noisy on my lancer 14800 Beverage Dispenser?
    • J
      John ColemanSep 23, 2025
      If your carbonator pump is noisy or cavitating, verify that the incoming supply water pressure to the carbonator pump is a minimum of 25 psi and a maximum of 50 psi.
  • O
    ohobbsAug 25, 2025
    Why is there insufficient soda flow from my lancer 14800 Beverage Dispenser?
    • J
      John ShawAug 25, 2025
      If you're experiencing insufficient soda flow from your Lancer Beverage Dispenser, ensure that the incoming CO2 pressure is between 70 and 75 psi. Also, check the shutoff valve on the mounting block to make sure it's fully open.
  • C
    Cindy ThomasAug 25, 2025
    How to fix excessive foaming in my lancer 14800?
    • M
      Michael GloverAug 26, 2025
      To resolve the issue of excessive foaming in your Lancer Beverage Dispenser: * Ensure the ice bin is full and allow the cold plate to re-stabilize. * Correct the incoming water or syrup temperature if it's too high. * Adjust the CO2 pressure downward, ensuring it remains above 70 psi. * Readjust and reset the ratio. * Clean the nozzle and diffuser. * Bleed air from the BIB lines.
  • G
    grosskatieAug 27, 2025
    What to do if no product is dispensed when the switch is activated on my lancer 14800, but the switch panel does light up?
    • M
      Matthew FrostAug 27, 2025
      If the switch panel lights up when activated, but no product is dispensed from your Lancer Beverage Dispenser, the issue could stem from: * A disconnected 25-pin valve harness. Turn off the power, reconnect the 25-pin harness, and restore power. * A faulty switch assembly, which would need replacement. * A faulty product solenoid, also requiring replacement.
  • T
    Trevor HorneSep 23, 2025
    Why is there insufficient water flow in my lancer 14800 for plain water drinks?
    • T
      Taylor CantuSep 23, 2025
      To address insufficient water flow for plain water drinks from your Lancer Beverage Dispenser, verify that the incoming supply water pressure to the plain water inlet is a minimum of 75 psi (maximum of 125 psi). Also, ensure that the shutoff valve on the mounting block is fully open. Additionally, check for any foreign debris in the water flow control and clean it out to ensure smooth spool movement. Finally, consider if there is a water filtration problem and service the water system as required.
  • C
    Cindy ColemanSep 13, 2025
    Why does my lancer 14800 push chute, ice door open, motor runs, but no ice dispenses?
    • W
      webersamanthaSep 13, 2025
      If the push chute opens the ice door, the motor runs, but no ice is dispensed (or the ice is of poor quality) from your Lancer Beverage Dispenser, it could be due to: * The dispenser being out of ice; fill the unit with ice. * A missing or damaged agitator pin; replace the agitator pin. * Poor ice quality; install water filtration/purification to the ice maker supply water.
  • J
    Julie ThorntonSep 12, 2025
    Why am I experiencing erratic ratio in my lancer 14800?
    • Y
      yrichardsSep 12, 2025
      If you're experiencing erratic ratio in your Lancer Beverage Dispenser, it could be due to the incoming water and/or syrup supply not being at the minimum flowing pressure; check and adjust the pressure. Additionally, foreign debris in the water and/or syrup flow control could be the cause; clean out any foreign material to ensure smooth spool movement. Lastly, the CO2 regulator might be malfunctioning; repair or replace as required.
  • S
    Samantha HerreraSep 12, 2025
    What to do if valve will not shut off on my lancer 14800 Beverage Dispenser?
    • J
      jamesperezSep 12, 2025
      If the valve on your Lancer Beverage Dispenser won't shut off, try activating the valve a few times to dislodge any debris in the solenoid seat. If this doesn't work, remove the solenoid coil and plunger and clean out any foreign material. If the issue persists, the solenoid plunger might be sticking, and you should replace the solenoid coil.
  • E
    eryanSep 4, 2025
    Why does the BIB pump on my Lancer Beverage Dispenser fail to restart after replacing the bag?
    • J
      jessica75Sep 4, 2025
      If the BIB pump on your Lancer Beverage Dispenser fails to restart after a bag replacement, make sure the BIB connector is tightly secured. If it is, the connector might be stopped up, requiring cleaning or replacement. Also, check for any kinks in the syrup line and straighten or replace the line if necessary.
  • P
    phillipspatrickSep 2, 2025
    Why is my lancer 14800 dispensing only water or only syrup?
    • M
      mckeematthewSep 2, 2025
      If your Lancer Beverage Dispenser is dispensing only water, no syrup, or syrup only, no water, consider the following: * The syrup BIB might be empty; replace as needed. * The water or syrup shutoff on the mounting block might not be fully open; ensure it is. * There might be an improper or inadequate water or syrup supply; check the supply. * The CO2 pressure to syrup pumps might be too low; ensure it's between 70-80 psi. * The BIB pump might be stalled or inoperative; check CO2 pressure and/or replace the pump. * There might be a kinked line; remove the kink or replace the line. * The CO2 regulator might be malfunctioning; repair or replace as required.

Summary

SPECIFICATIONS

INSTALLATION

SELECTING COUNTER LOCATION

Guidelines for choosing an appropriate installation site.

INSTALLING THE DISPENSER

Steps for physically setting up the beverage dispenser.

CLEANING AND SANITIZING INSTRUCTIONS

HOW TO OPERATE AND ADJUST THE LANCER FS30

TROUBLESHOOTING GUIDE FOR FS30 DISPENSER

ILLUSTRATIONS AND PARTS LISTINGS

FINAL ASSEMBLY

Exploded view and parts list for the final assembly.

PELLET ICE ASSEMBLY AND PARTS LISTING

Parts list and diagram for pellet ice assembly.

WIRING DIAGRAM - 115 V;60 HZ (Figure Schematics)

Electrical wiring schematic for 115V/60Hz units.

PLUMBING DIAGRAM WITH VALVE WIRING

Plumbing diagram illustrating valve connections.

lancer 14800 Series Specifications

General IconGeneral
Brandlancer
Model14800 Series
CategoryBeverage Dispenser