Why is my Landa PDE2-1100 pump running but the pressure is low after installation?
- DDr. Matthew HernandezSep 8, 2025
Low pressure after installation can occur if the pump is sucking air. Check the water supply and look for any signs of air seepage. It could also be caused by sticking check valves, which you should inspect and clean or replace. Other potential causes include a faulty unloader valve seat (check and replace if needed), an incorrectly sized nozzle (check and replace if needed), or worn piston packing (check and replace if needed). Also, a faulty or misadjusted unloader valve can be the reason.