How to troubleshoot low water temperature in Landa PGDC?
- Kkatie13Aug 25, 2025
Low water temperature in your Landa Pressure Washer may be due to several reasons. Start by ensuring you are using clean and proper fuel. Low fuel pressure can also cause this issue, so increase the fuel pressure. A weak fuel pump should be checked and replaced if needed. If the fuel filter is partially clogged, replace it. Soot build-up on the coils can prevent heat transfer, so clean the coils. Finally, ensure you are using the proper burner nozzle as per the specifications.