Why is my Landa VHP Pressure Washer relief valve leaking water?
J
Jennifer HoffmanSep 3, 2025
If the relief valve is leaking water on your Landa Pressure Washer, it could be due to:
* The wrong nozzle size or debris in the nozzle. Clean or replace it with the correct nozzle.
M
Mr. Derrick JohnsonSep 1, 2025
Why won't the pilot stay on in my Landa VHP Pressure Washer?
S
Stephen JonesSep 1, 2025
If the pilot ignites but will not stay on when the gas cock dial is released on your Landa Pressure Washer, it could be:
* The pilot is too far away from the thermocouple. Adjust the thermocouple closer to the flame.
* The thermocouple is loose at the regulator safety valve. Tighten it to a firm fit.
K
Kelly HarrisAug 31, 2025
Why does my Landa VHP Pressure Washer pilot not light?
K
Krista FullerAug 31, 2025
If the pilot on your Landa Pressure Washer does not light, it could be due to:
* A closed manual pilot valve. Open the pilot valve.
* A gas leak in the pilot. It is recommended to call a qualified serviceman.
* A problem with the piezo ignitor. Adjust the spark gap and secure the wires.
S
sylvia81Aug 30, 2025
Why is my Landa VHP burner smoking?
J
John SotoAug 30, 2025
If your Landa Pressure Washer burner is smoking, it may be due to a stack restriction.
A
arroyoryanAug 28, 2025
What to do if my Landa Pressure Washer is not steaming?
B
Barbara PalmerAug 29, 2025
If your Landa Pressure Washer is not steaming, consider these potential causes:
* Ensure the steam valve is open (counterclockwise).
* Verify the burner switch is in the "ON" position.
* The coil may be dirty or sooty.
* The steam valve could be clogged; try cleaning or replacing it.
L
lindsaybrewerAug 27, 2025
What causes pulsation in my Landa VHP Pressure Washer?
B
bradleyjuliaAug 27, 2025
Pulsation in your Landa Pressure Washer is often caused by a faulty pulsation damper. Check the precharge; if it's low, recharge it or install a new one.
S
Steven EspinozaAug 27, 2025
What to do if my Landa VHP Pressure Washer pump runs rough with low pressure?
J
Jacob BrownAug 27, 2025
If your Landa Pressure Washer pump runs extremely rough and the pressure is very low, the issue could be:
* A restricted inlet or air entering the inlet plumbing. Ensure proper size inlet plumbing and check for an airtight seal.
* Inlet restrictions and/or air leaks, or a stuck inlet or discharge valve. Replace worn cup or cups, clean out any foreign material, and replace worn valves.
J
John AndrewsAug 25, 2025
Why is my Landa VHP pump so noisy?
J
jennifermillerAug 26, 2025
A noisy pump in your Landa pressure washer can be due to:
* Air in the suction line. Check the water supply and connections on the suction line.
* Broken or weak inlet or discharge valve springs. Check and replace if necessary.
* Excessive matter in valves. Check and clean if necessary.