Operating and
Installation Instruction
Ultrasonic heat and cooling meter
ULTRAHEAT®T230
13.07.2020
Translation
T230
Note: In the text below, the term meter refers both to
the heat meter and to the cooling meter and the com-
bined heat and cooling meter, unless otherwise speci-
fied.
Note: The meter cannot be opened without damaging
the security seal.
The meters may only be used in building service
engineering plants and only for the applications
described.
The local regulations (installation etc.) must be ad-
hered to.
The operating conditions according to the type plate
must be complied with during use. Non-compliance
can result in hazardous situations and the expiry of all
claims arising from liability for defects as well as
liability based on any expressly granted guarantees.
Do not under any circumstances carrying out welding,
drilling or soldering work close to the meter.
The meter is only suitable for circulating water in
heating systems.
The meter is not suitable for drinking water.
Requirements for circulating water (CEN/TR 16911:
2016).
Only personnel, trained in the installation and opera-
tion of meters in heating and cooling systems, may
install and remove the meter.
Only install or remove the meter when the pipes are
pressure-less.
After installing the meter, check the leak-tightness of
the system.
Guarantee and calibration validity will lapse if the
calibration relevant security seal is broken.
Only clean the meter from outside with a soft, lightly
wetted cloth. Do not use any spirit or cleaning sol-
vent.
As far as disposal is concerned, the meter is a waste
electronic appliance in the sense of European Di-
rective 2012/19/EU (WEEE) and it must not be dis-
posed of as domestic waste. The relevant national,
legal regulations must be observed as the appliance
must be disposed of via the channels provided for
this purpose. The local and currently valid legislation
must be observed.
The meter contains lithium batteries. Do not dispose
of the meter and the batteries with domestic waste.
Observe the local stipulations and laws on disposal.
You can return the lithium batteries to the manufac-
turer for appropriate disposal following use. When
shipping please observe legal regulations, in particu-
lar, those governing the labelling and packaging of
hazardous goods.
Do not open the batteries. Do not bring batteries into
contact with water or expose to temperatures above
80 °C.
The meter does not have any lightning protection.
Ensure lightning protection via the in-house installa-
tion.
Note: At a heat meter or combined heat/cooling
meter the mounting place of the flow sensor cold
side is equivalent to return . The mounting
place of the flow sensor hot side is equivalent to flow
.
Note: At a cooling meter the mounting place of the
flow sensor hot side is equivalent to the return .
The mounting place of the flow sensor cold side is
equivalent to flow .
Note: At a meter with an adjustable mounting
place , the mounting place hot side is displayed
as . The mounting place cold side is dis-
32 18 101 003
k

Other manuals for Landis+Gyr ULTRAHEAT T230

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Landis+Gyr ULTRAHEAT T230 and is the answer not in the manual?

Landis+Gyr ULTRAHEAT T230 Specifications

General IconGeneral
Measuring PrincipleUltrasonic
Nominal Flow Rate qp2.5 m³/h
Pressure RangeUp to 16 bar
Power SupplyBattery
Communication InterfacesM-Bus, Wireless M-Bus
Ambient Temperature Range5 to 55 °C
DimensionsDepends on model
WeightDepends on model
Accuracy ClassClass 2