EasyManuals Logo

Landis+Gyr ULTRAHEAT XS User Manual

Landis+Gyr ULTRAHEAT XS
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Ultrasonic Heat Meter 2WR6
Operating instructions
UH304-101l
ULTRAHEAT XS
Ultrasonic Heatmeter ULTRAHEAT
®
XS Subject to change without prior notice UH 304 – 101k 1/2
Introduction
The ULTRAHEAT
®
XS heat meter is a measuring instrument for
physically correct recording of heat consumption. It is required to
be certified by law in Germany and many other countries. The
device consists of a volume measuring unit, two permanently
connected temperature sensors, and an electronic unit that calcu-
lates the heat consumption from the volume flow and temperature
difference.
The volume measuring unit is a non-wearing ultrasonic measuring
device without mechanically moving parts. The long-life battery is
designed for the calibration validity period. ULTRAHEAT
®
XS
cannot be opened without breaking the calibration seal.
The heat meter must only be operated under the conditions stated
in the device sheet and on the rating plate.
Information on the Display
The displays of the heat meter are structured on several levels
and may deviate from the standard described here. Each short
press of the button switches to the next display of the user loop
(level 1).
indicates what sort of display it is.
User Loop
0054567 kWh
Cumulated heat quantity
00065.43 m³
Cumulated volume
888888 kWh
Segment test
Info
F - - -
Error message on fault with
fault number
Info
Pressing the button for 10 seconds switches from the user loop to
the service loop (level 2).
Exiting the service loop by pressing the button for 3s or auto-
matically after 30 minutes.
Service Loop
0.534
m³/h Current flow rate
22.9 kW Current heat power
84 47 °C Current supply-return temperature
04.06.02 D Date
786 Bh Operating hours
56 Fh Missing hours
3792701 G Device number, 7-digit
Info
PulSE CH Remote reading option (optional)
Info
123 A Primary address when option M-Bus
Info
2345678 K Customer number, 7-digit
Info
18.02.01 F0 Date stamp for F0 prewarning
Info
3- 01 FW Firmware version
Info
31.12.01 V Previous year's day of storage
Prev. year
0034321 kWh Heat previous year on set day
Prev. year
00923.12 Volume previous year on set day
Prev. year
12 Fh Missing hours previous year
Prev. year
- -.- -.- - C Code entry for parameterization
Info
01.06.02 M Previous month's 1-15 day of storage
Prv. month
After pressing button for 3s:
0034321 kWh Heat previous month on set day
Prv. month
00923.12 Volume previous month on set day
Prv. month
12 Fh Missing hours previous month on set
day
Prv. month
Monthly Values
The calculator stores the following values for 15 months at each
end of month
- Heat (meter reading)
- Volume (meter reading)
- Missing hours (meter reading)
From the month set day display, press the service button for 3s to
enter the previous month's values.
The month values can also be read out via the optical interface.
Fault Codes and IDs
The heat meter constantly performs self-diagnosis and can dis-
play various faults.
These operating instructions have to be handed over to the end user
3250 004 101 l