LW 300 E / LW 450 E
Page A - 65
A
MAINTENANCE AND SERVICE
Leak test
Leak test as follows:
Disconnect the compressor from the electrical power
supply and protect against unexpected restart.
Remove the cover of the switch box.
Switch on the leak test switch (solenoid valves will be
deactivated!).
Mount the cover of the switch box.
Connect the compressor to the electrical power supply.
• Close filling valves.
• Start the compressor.
Switch off the compressor at a pressure of approx. 150
bar.
Verify the compressor for release noises. (A slight hiss of
the air inlet filter nozzle can be ignored). If release noises
occur, localise blow off position(s).
Switch off the compressor.
Disconnect the compressor from the electrical power
supply and protect against unexpected restart.
Remove the cover of the switch box.
Switch off the leak test switch (solenoids will be activa-
ted!).
Mount the cover of the switch box.
Connect the compressor to the electrical power supply.
The leak test is now completed.
Note
Do not fill any tank during test phase!
i
Switch box
Leak test switch (lower)
Version: 261012-001 E