EasyManua.ls Logo

Lang 124T - 480 Vac

Lang 124T
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
15
31
1
LG48 / 148T
LG36 / 136T
LG24 / 124T
L1 L2 L3
4
NOTE: LG60 & LG72 HAVE TWO POWER SUPPLY CONNECTIONS
LG60: CONN # 1 USE LG36
CONN # 2 USE LG24
LG72: CONN # 1 USE LG36
CONN # 2 USE LG36
1 GRIDDLE ELEMENTS
2 GRIDDLE PILOT LAMP
3 GRIDDLE THERMOSTAT
4 TERMINAL BLOCK
3
2
32
87
* NUMBER
***
**
6
*
5
*
13
3
29
2
30
** *
1
4
*
3
*
11
3
27
2
28
** *
1
2
*
1
*
9
3
25
2
26
** *
1
MODELS:
48OV, 3PH Electric Thermostatic Griddles
2M-61114-02 Rev B
11/7/1997
SERVICE CONNECTIONS
MODEL
24
36
48
2,51,4
1,4,7 2,5,8
1,4
L2
2
3,6
3,6
L3
3
L1
THREE PHASE