INSTALLATION CONT’D
Correct manifold pressures are:
5 inches water column for natural gas
10 inches water column for propane
When replacing the plug in the manifold, a pipe joint compound or sealant
should be used that is resistant to the action of liquid petroleum gas.
Initial adjustments are the responsibility of the installer and are not chargeable
to Star Manufacturing International.
After the griddle is in its final position, adjust the legs to create 1/8 inch slant
from back to front. This will allow the grease to run into the grease gutter and
provide the proper combustion air for the burners.