5: Commands and Levels
EDS-MD® Wired IoT Device Gateway Command Reference 625
Removes the name of this line.
Uses a parity bit on the line for even parity.
Does not use a parity bit on the line.
Uses a parity bit on the line for odd parity.
Uses no protocol on the line.
Applies tunnel protocol on the line.
Asserts line status with current configured values.
Displays the current status.
Shows the command mode settings for the current
line.
Displays the last 20 commands entered during the
current CLI session.
Displays the current configuration.
Shows the line statistics.
Disables the line so data cannot be sent/received.
Enables the line so data can be sent/received.
Uses one stop bit after data on the line.
Uses two stop bits after data on the line.
Enters the configure-terminal level. <line> = number
of the terminal line (serial port) to be configured.
Enters the configure-terminal level for the network.
Sets the threshold in bytes. After this many bytes
are received, they are forwarded without delay.
Enters the tunnel level. <line> = number of the
tunnel line (serial port) to be configured.
Stores the current configuration in permanent
memory.
Sets the xoff character for use with software flow
control on this line. The character may be input as
text, control, decimal, or hex. A control character
has the form <control>C. A decimal value character
has the form \99. A hex value character has the
form 0xFF.
Sets the xon character for use with software flow
control on this line. The character may be input as
text, control, decimal, or hex. A control character
has the form <control>C. A decimal value character
has the form \99. A hex value character has the
form 0xFF.
line 1 (config-mach10-line:1) level commands
Sets the command delimiter.
content check interval <hours>
Sets the firmware and configuration check interval.
default command delimiter
Restores the command delimiter.
default content check interval
Restores the default firmware and configuration
check interval.
default status update interval
Restores the default status update interval.
Exits to the config-mach10 level.
Change to line configuration level.
Restores the default Project Tag.