5: Commands and Levels
EDS-MD® Wired IoT Device Gateway Command Reference 626
Displays the current configuration.
Displays the last 20 commands entered during the
current CLI session.
Disables command processing on line.
Enables command processing on line.
status update interval <minutes>
Sets the status update interval.
Stores the current configuration in permanent
memory.
line 2 (line:2) level commands
Continuously displays line statistics.
baud rate <bits per second>
Sets the line speed. <bits per second> = the speed.
Standard speeds include 1200, 2400, 4800, 9600,
19200, and so on.
Sets the serial counters to zero.
Sets the current line to always be in command
mode.
command mode echo serial string disable
Disables user-defined serial boot string to be
echoed in the CLI.
command mode echo serial string enable
Enables user-defined serial boot string to be echoed
in the CLI.
command mode serial string
Enables user to enter a custom string at boot time to
enter command mode.
command mode serial string <string>
Sets a string that can be entered at boot time to
enter command mode. <string> = text with possible
binary characters. Within [] use binary decimal up to
255 or hex up to 0xFF. Within {} specify decimal
milliseconds time delay.
command mode signon message <string>
Sets a sign-on message that is sent from the serial
port when the device boots and when the line is in
command mode. <string> = text with possible binary
characters. Within [] use binary decimal up to 255 or
hex up to 0xFF.
command mode wait time <milliseconds>
Sets boot-up wait time for command mode serial
string. <milliseconds> = wait time.
configure current settings
Configures line with the current value of settings.
Uses seven bits for data on the line.
Uses eight bits for data on the line.
Restores the default speed of 9600 bits per second.
Restores the default of eight data bits.
Restores the default of no flow control.
Restores the default of no parity.
Restores the default of one stop bit.
Restores the factory default threshold.
Restores the default xoff character on this line.
Restores the default xon character on this line.
Exits to the enable level
Uses hardware (RTS/CTS) flow control on the line.
Does not provide flow control on the line.