EasyManua.ls Logo

Lantronix UDS2100 - User Manual

Lantronix UDS2100
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Part Number 900-448
Revision F June 2015
UDS2100
Device Server User Guide

Table of Contents

Other manuals for Lantronix UDS2100

Questions and Answers

  • P
    pageleslieAug 20, 2025
    How to fix 'Wrong Password' error when upgrading Lantronix UDS2100 Server firmware?
    • C
      Charles RichardsonAug 21, 2025
      To resolve the "Wrong Password" error when upgrading the firmware on your Lantronix Server using DeviceInstaller, download the correct firmware file from the Lantronix website, as the file you're currently trying to load is likely the incorrect one for the UDS.
  • S
    Susan CordovaAug 22, 2025
    Why can't I connect to my Lantronix UDS2100, even with correct settings?
    • L
      Lauren YoungAug 22, 2025
      The most likely reason for connection issues with the Lantronix Server is a mismatch in serial settings. Ensure that the serial settings for both the serial device and the device server are identical. The default serial settings for the device server are RS-232, 9600 baud, 8 character bits, no parity, 1 stop bit, and no flow control.
  • A
    Andrew ReynoldsAug 25, 2025
    What to do if my computer cannot connect to port 30718 on Lantronix UDS2100?
    • M
      Michelle McleanAug 25, 2025
      To resolve the issue of your computer being unable to connect to port 30718 (77FEh) on the Lantronix Server, ensure that port 30718 (77FEh) is not blocked by any router on your network. Also, verify that port 77FEh is not disabled within the Security settings of the device server.
  • R
    Renee PerkinsAug 26, 2025
    How to connect to the correct socket of Lantronix UDS2100?
    • J
      Jason JohnstonAug 26, 2025
      If you are sure that the serial port setting is correct, then you may not be connecting to the correct socket of the Lantronix Server. Use the Connect Mode option C0 for making a connection to the UDS from the network. Use Connect Mode option C1 or C5 for a connection to the network from the UDS.
  • G
    Gabriela GrahamAug 28, 2025
    What to do if IP address is not on logical subnet of Lantronix UDS2100?
    • R
      rebeccafloydAug 28, 2025
      To address the issue where the IP address you're assigning isn't on your logical subnet for the Lantronix Server, ensure your PC has an IP address within the same logical subnet you're attempting to assign to the device server.
  • E
    Erin LeAug 29, 2025
    How to enter the Ethernet address correctly with the ARP command for Lantronix UDS2100?
    • K
      kaylagrayAug 29, 2025
      To correct the issue of entering the Ethernet address incorrectly with the ARP command for your Lantronix Server, confirm that the Ethernet address you entered is correct. The Ethernet address may only include numbers 0-9 and letters A-F. In Windows and usually in Unix, the segments of the Ethernet address are separated by dashes. In some forms of Unix, the Ethernet address is segmented with colons.
  • C
    conradderrickAug 31, 2025
    How to resolve insufficient rights to use command on Lantronix UDS2100 Server?
    • R
      rsparksAug 31, 2025
      To resolve the issue of insufficient user rights on your PC to use a command on the Lantronix Server, have someone from your IT department log you in with sufficient rights.
  • J
    Justin MooreSep 2, 2025
    Why can I ping Lantronix Server but not Telnet to port 9999?
    • W
      William PhelpsSep 2, 2025
      If you can ping the Lantronix Server but can't Telnet to it on port 9999, there might be an IP address conflict on your network, you might not be Telneting to port 9999, or the Telnet configuration port (9999) might be disabled in the device server's security settings. To resolve this, turn off the device server, then open the command prompt on your computer and enter these commands: * `ARP -D X.X.X.X` (replace `X.X.X.X` with the device server's IP address) * `PING X.X.X.X` (replace `X.X.X.X` with the device server's IP address) If you get a response after the ping, there is a duplicate IP address on the network. If there is no response, use the serial port to check if Telnet is disabled.
  • R
    Ricky PhamSep 3, 2025
    What to do if Lantronix UDS2100 is not communicating with the connected device?
    • P
      Paul VelezSep 3, 2025
      If the Lantronix Server appears correctly set up but isn't communicating with your attached device across the network, ensure your serial port settings are correct and that you are connecting to the correct socket on the device server. Also, verify the device server is properly set up to make a solid socket connection to the network. * Use Connect Mode option `C0` for making a connection to the UDS from the network. * Use Connect Mode option `C1` or `C5` for a connection to the network from the UDS.
  • R
    Robert SolisSep 5, 2025
    How to fix 'No Connection With The Device Server' message on Lantronix Server?
    • M
      mitchellmichaelSep 5, 2025
      If you encounter the "No Connection With The Device Server" message when trying to connect to the Web Manager within the Lantronix Server, it means your computer can't connect to port 30718 (77FEh) on the device server. Ensure that port 30718 (77FEh) isn't blocked by any router on your network and that port 77FEh isn't disabled within the Security settings of the device server.

Summary

Installation of UDS2100

Using DeviceInstaller

Assigning an IP Address with DeviceInstaller

Manual process to assign an IP via DeviceInstaller.

Accessing UDS2100 Using DeviceInstaller

Steps to locate and select the UDS2100 in DeviceInstaller.

Viewing Current Configuration

How to check the unit's current settings in DeviceInstaller.

Assigning IP Address via Serial Port Login

Assigning IP address and network settings using a serial connection.

Configuration Using Web Manager

Network Configuration

Settings for network parameters like IP, Subnet Mask, and Gateway.

Automatic IP Address Configuration

Explains DHCP, BOOTP, AutoIP for automatic IP assignment.

Static IP Address Configuration

Manual configuration of IP, Subnet Mask, Gateway, and DNS.

Server Configuration

General server-side settings for the UDS2100.

Channel 1 and Channel 2 Configuration

Defines serial port behavior for network communication.

Serial Settings

Configuration of baud rate, data bits, parity, etc.

Connection Settings - TCP

TCP specific connection parameters for channels.

Connection Settings - UDP

UDP specific connection parameters for channels.

Apply Settings

How to save and apply configuration changes to the device.

Apply Defaults

How to reset settings to factory defaults.

Configuration via Telnet or Serial Port (Setup Mode)

Accessing Setup Mode

How to enter Setup Mode via Telnet or serial port.

Serial Port Connection

Steps to access Setup Mode via a serial connection.

Setup Mode: Server Configuration

Server Configuration (Option 0)

Basic network parameters like IP, Gateway, and Netmask.

IP Address Configuration in Setup Mode

Manual IP assignment and DHCP/BOOTP/AutoIP options.

Set Gateway IP Address

Configuration of the default gateway address.

Netmask Configuration

Defines the subnet mask for IP addressing.

Set DNS Server IP Address

Configuration of the DNS server address.

Change Telnet;Web Configuration Password

Setting a password for setup access.

Setup Mode: Channel Configuration

Channel 1 Configuration

Configuring serial port settings for Channel 1.

Interface (I;F) Mode

Setting serial interface parameters (RS232, RS485).

Flow Control Settings

Configuration of flow control settings for serial ports.

Port Number

Setting the TCP port number for connections.

Connect Mode

Defining how connections are made and handled.

Modem Mode Configuration

Configuring the unit for modem emulation.

Remote IP Address

Setting the destination IP for outgoing connections.

Remote Port

Setting the destination port for outgoing connections.

Channel (Port) Password

Setting a password for serial port access.

Setup Mode: Advanced Settings

Expert Settings (Option 5)

Advanced configuration options not available via Web Manager.

Security Settings (Option 6)

Security-related configuration options.

Firmware Upgrades

Monitor Mode

Troubleshooting and Contact Information

Connections and Pinouts

Technical Specifications

Alternative Ways to Assign an IP Address

Lantronix UDS2100 Specifications

General IconGeneral
Isolation1.5 kV
CertificationFCC, C/UL, CSA, VCCI, CE, TUV, CTick
Serial interface typeRS-232/422/485
Serial ports quantity2
Ethernet LAN data rates10, 100 Mbit/s
Electrostatic Discharge (ESD) protection15 kV
USB 2.0 ports quantity0
Supported network protocolsARP, UDP, TCP, ICMP, Telnet, TFTP, AutoIP, DHCP, HTTP, SNMP TCP, UDP, Telnet, TFTP, RFC2217
Built-in processorLantronix DSTNI-EX
Processor frequency48 MHz
Compatible operating systemsWindows 98/ME/NT/2000/XP
Flash memory2 MB
RAM capacity0.256 MB
LED indicatorsLAN, Y
Storage temperature (T-T)-40 - 85 °C
Operating temperature (T-T)0 - 60 °C
Operating relative humidity (H-H)10 - 90 %
Input voltage9 - 30 V
Weight and Dimensions IconWeight and Dimensions
Weight400 g
Dimensions (WxDxH)72 x 23 x 95 mm

Related product manuals