5: Configuration Using Web Manager
UDS2100 Device Server User Guide 33
With Passive Connect
Select Yes to clear the output buffer with a connection initiated
from the network to the device. The default setting is No.
At Time of Disconnect
Select Yes to clear the output buffer when the network
connection to or from the device is disconnected. The default
setting is No.
3. When you are finished, click the OK button.
4. On the main menu, click Apply Settings.
Connection Settings - TCP
To configure a channel’s TCP settings:
1. On the main menu, click Connection. The Connection Settings window for
the channel displays.
Figure 5-7. TCP Connection Settings
2. In the available fields, enter or modify the following information:

Table of Contents

Other manuals for Lantronix UDS2100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix UDS2100 and is the answer not in the manual?

Lantronix UDS2100 Specifications

General IconGeneral
Isolation1.5 kV
CertificationFCC, C/UL, CSA, VCCI, CE, TUV, CTick
Serial interface typeRS-232/422/485
Serial ports quantity2
Ethernet LAN data rates10, 100 Mbit/s
Electrostatic Discharge (ESD) protection15 kV
USB 2.0 ports quantity0
Supported network protocolsARP, UDP, TCP, ICMP, Telnet, TFTP, AutoIP, DHCP, HTTP, SNMP TCP, UDP, Telnet, TFTP, RFC2217
Built-in processorLantronix DSTNI-EX
Processor frequency48 MHz
Compatible operating systemsWindows 98/ME/NT/2000/XP
Flash memory2 MB
RAM capacity0.256 MB
LED indicatorsLAN, Y
Storage temperature (T-T)-40 - 85 °C
Operating temperature (T-T)0 - 60 °C
Operating relative humidity (H-H)10 - 90 %
Input voltage9 - 30 V