UDS2100 Device Server User Guide 60
9: Setup Mode: Advanced Settings
Expert Settings (Option 5)
Note: You can change these settings using Telnet or serial connections
only, not on the Web Manager.
Caution: Changing the expert settings can drastically affect the
performance and access to the product. These settings should only
be changed by an experienced network administrator.
Select 5 to configure expert settings.
Figure 9-1. Expert Settings
TCP Keepalive time in s (1s - 65s; 0s=disable): (45) ?
ARP Cache timeout in s (0s - 600s) : (600) ?
CPU performance (0=Regular, 1=Low, 2=High): (0) ?
Disable Monitor Mode @ bootup (N) ?
HTTP Port Number : (80) ?
MTU Size (512 - 1400): (1400) ?
TCP Re-transmission Timeout (500 - 4000) (ms): (500) ?
Enable alternate MAC (N) ?
Ethernet connection type: (0) ?
TCP Keepalive Time In Seconds
This option allows you to change how many seconds the unit waits during a silent
connection before attempting to see if the currently connected network device is
still on the network. If the unit gets no response, it drops that connection. The
default setting is 45.
TCP Keepalive time in s (1s – 65s; 0s=disable): (45)? _
ARP Cache Timeout In Seconds
Whenever the unit communicates with another device on the network, it adds an
entry into its ARP table. The ARP Cache timeout option allows you to define how
many seconds (1-600) the unit will wait before timing out this table. The default
setting is 600.
ARP Cache timeout in s (0s - 600s) : (600) ?
CPU Performance
Select the UDS2100’s performance mode. Higher performance settings require
more energy. Low is 26 Mhz; Regular is 48 Mhz; High is 88 Mhz. The default is
Regular.
CPU performance (0=Regular, 1=Low, 2=High): (0)

Table of Contents

Other manuals for Lantronix UDS2100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix UDS2100 and is the answer not in the manual?

Lantronix UDS2100 Specifications

General IconGeneral
Isolation1.5 kV
CertificationFCC, C/UL, CSA, VCCI, CE, TUV, CTick
Serial interface typeRS-232/422/485
Serial ports quantity2
Ethernet LAN data rates10, 100 Mbit/s
Electrostatic Discharge (ESD) protection15 kV
USB 2.0 ports quantity0
Supported network protocolsARP, UDP, TCP, ICMP, Telnet, TFTP, AutoIP, DHCP, HTTP, SNMP TCP, UDP, Telnet, TFTP, RFC2217
Built-in processorLantronix DSTNI-EX
Processor frequency48 MHz
Compatible operating systemsWindows 98/ME/NT/2000/XP
Flash memory2 MB
RAM capacity0.256 MB
LED indicatorsLAN, Y
Storage temperature (T-T)-40 - 85 °C
Operating temperature (T-T)0 - 60 °C
Operating relative humidity (H-H)10 - 90 %
Input voltage9 - 30 V
Weight and Dimensions IconWeight and Dimensions
Weight400 g
Dimensions (WxDxH)72 x 23 x 95 mm

Related product manuals