Shenzhen Qilin Laser Application Technology Co., Ltd.
NOTICE
1. The use of laser welding system with laser welding machine includes a laser, water-cooled
machine, laser welding system, laser welding head multiple control module, to avoid interference,
ensure from argon arc welding machine two protect welder and interfere with the larger related
equipment, to ensure a safe distance in 5 meters above conditions allow independent space to
ensure that the laser welding machine
2. In order to reduce equipment leakage or static electricity, ensure that handheld laser welding
equipment use effective ground wire.
3. Please confirm again whether the bushing joint is properly connected and locked, and wrap it
with insulation tape after locking.
4. Check whether the laser head and optical fiber are tightly connected. After confirming that the
connection is normal, you can use adhesive tape to seal and wrap it to ensure that dust does not
enter the laser head cavity.
5. To check whether there is water seepage phenomenon, cavity cavity in the body in water,
without professional training may not loose screws, prevent water from entering the chamber
internal protection lens drawer is normal examination.
6. Make sure that the seal properly, protect the lens replaced to ensure the alcohol to clean laser
external besmirch, at least more than five times, make sure that the replacement lenses
environment clean without wind can change lenses.
7. The inside of the laser head is very complicated. In order to avoid short circuit, please stay away
from water and ensure that no liquid can be sprayed on the laser head.
8. Laser head refuse to use strong wind to blow and clean the laser head, only use alcohol and
dust-free cloth to wipe.
9. The laser head is installed with a digital motor, must be used gently, to prevent motor failure.
10. When the laser head is not in use, please repeatedly use the system gas to blow air, so that the
dust is discharged, and remove the copper nozzle, seal with sealing tape, install the copper nozzle
to blow air more than 2 times before using.
11. Continuous interruption of power supply will damage the welding control system, please
provide continuous and reliable power supply!
12. The external safety lock is at a high level of 24V. Do not short-connect it with the GND housing
of the aviation plug of the system cable, or do not collide with each other during installation,
otherwise the short circuit may burn the power supply or the main control board.